Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
705 records match for Intuitive Surgical, Inc.
309 death reports2002–20261 registryClear
Narrow it down
What happened
Country
Year
Not graded by the source2021-06-09FDA MAUDEda Vinci Surgical System2955842-2021-10818da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A DA VINCI-ASSISTED RIGHT PULMONARY LOBECTOMY PROCEDURE, THE PATIENT DEVELOPED A POSTOPERATIVE CHYLOTHORAX. THE SURGEON COMMENTED THAT THE SEALING OF THE SYNCHROSEAL MAY BE UNSATISFACTORY. THE PATIENT WAS HOSPITALIZED AND UNDER OBSERVATION. IT IS UNKNOWN IF ANY MEDICAL/SURGICAL INTERVENTION WAS TAKEN. THE PROCEDURE WAS COMPLETED AS PLANNED. ON (B)(6) 2021, INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE ISI CLINICAL SALES REPRESENTATIVE (CSR), WHO SPOKE TO THE CUSTOMER, AND OBTAINED THE FOLLOWING INFORMATION: THE SYSTEM, INSTRUMENT AND ACCESSORY WERE INSPECTED BEFORE USE AND THERE WAS NOTHING OUT OF THE ORDINARY. THERE WAS NO MALFUNCTION OF AN ISI SYSTEM, INSTRUMENT OR ACCESSORY THAT OCCURRED. THERE WAS NO EVIDENCE OF INSUFFICIENT SEALING/CAUTERY ISSUE/INTRA-OPERATIVE COMPLICATION OBSERVED DURING THE PROCEDURE AND THE SURGERY WAS COMPLETED AS PLANNED. THERE WAS NO UNEXPECTED BLEEDING OBSERVED DURING THE PROCEDURE. THE CUSTOMER CONFIRMED THAT THE TISSUE BUNDLE WAS LESS THAN 5 MM, THE TISSUE FIT IN THE JAWS OF THE INSTRUMENT, THERE WAS NO TISSUE TENSION, NO CONTACT WITH HARD MATERIAL, NO EVIDENCE OF VESSEL CALCIFICATION AND THE INSTRUMENT JAWS WERE NOT
cause not established2955842-2021-10818Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-09FDA MAUDEda Vinci Surgical System2955842-2021-10794da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10794Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-09FDA MAUDEda Vinci Surgical System2955842-2021-10780da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS INITIALLY REPORTED THAT DURING A DA VINCI-ASSISTED MYOMECTOMY SURGICAL PROCEDURE, THE HARMONIC ACE WAS FOUND TO HAVE A MELTED TEFLON PAD. FRAGMENTS FROM THE INSTRUMENT REPORTEDLY FELL INSIDE THE PATIENT DURING AN INSTRUMENT TIP OR ACCESSORY COLLISION AND WERE "VERY HARD TO BE RETRIEVED." THE SURGEON RETRIEVED THE FRAGMENTS WITH A BACKUP INSTRUMENT AND NOTED CONCERN ABOUT THE QUALITY OF THE TEFLON PAD. THE PROCEDURE WAS COMPLETED WITH NO REPORT OF PATIENT HARM, ADVERSE OUTCOME, OR INJURY. THE FRAGMENTS ARE NOT AVAILABLE TO BE RETURNED FOR ANALYSIS. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NO DAMAGE IDENTIFIED. THE INSTRUMENT WAS IN USE FOR APPROXIMATELY 10 TO 20 MINUTES BEFORE THE ISSUE. ALL THE FRAGMENTS WERE RETRIEVED DURING THE SAME PROCEDURE AND CONFIRMED WITH VISUAL INSPECTION. NO ADDITIONAL SURGICAL PROCEDURE WAS REQUIRED TO REMOVE THE FRAGMENT. IT WAS UNKNOWN WHAT CAUSED THE BREAKAGE TO OCCUR. THE REPORTER NOTED THAT THE INSTRUMENT DID NOT COLLIDE WITH ANY HARD MATERIALS OR OTHER INSTRUMENTS AS WAS INITIALLY REPORTED. THERE WAS NO PATIENT INJURY
cause not established2955842-2021-10780Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-08FDA MAUDEda Vinci Surgical System2955842-2022-12416da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: INTUITIVE SURGICAL INC. (ISI) BECAME AWARE OF A EUROPEAN UROLOGY OPEN SCIENCE ARTICLE TITLED, ¿SALVAGE VERSUS PRIMARY ROBOT-ASSISTED RADICAL PROSTATECTOMY: A PROPENSITY-MATCHED COMPARATIVE EFFECTIVENESS STUDY FROM A HIGH-VOLUME TERTIARY CENTRE¿ (NATHAN, A., FRICKER, M., ET AL., 2021). WITHIN THE CLINICAL JOURNAL ARTICLE, IT WAS CITED -ONE PATIENT SUFFERED FROM A HEMATOMA REQUIRING REOPERATION AND WASHOUT AFTER HIFU THERAPY. ON 15-JUN-2021, ISI OBTAINED THE FOLLOWING ADDITIONAL INFORMATION FROM THE AUTHOR REGARDING THE REPORTED EVENT: IT WAS REPORTED THAT THE DURING PORT INCISION, THERE WAS A VESSEL (VEIN) INJURY. AS A RESULT, THE PATIENT EXPERIENCED A HEMATOMA. THE ESTIMATED BLOOD LOSS INTRA-OPERATIVELY WAS 250-500MLS. THERE WAS PROCEDURE FOR A WASHOUT AND HEMOSTASIS. THERE WAS NO BLOOD TRANSFUSION ADMINISTERED TO THE PATIENT. THE SURGEON HAD CONFIRMED THERE WAS NO RELATION TO THE DA VINCI PRODUCT. HOWEVER, IT IS UNKNOWN IF THE TROCAR WAS AN ISI PRODUCT OR A THIRD-PARTY PRODUCT. AT THIS TIME, IT WAS UNCONFIRMED AS TO WHETHER A DA VINCI SURGICAL SYSTEM WAS INVOLVED IN THE REPORTED EVENT AND THERE IS NO KNOWN ALLEGATION OF A MALFUNCTION OF A DA VINCI PRODUCT.
cause not established2955842-2022-12416Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-08FDA MAUDEda Vinci Surgical System2955842-2021-10764da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A DA VINCI ASSISTED PROSTATECTOMY SURGICAL PROCEDURE, THE PATIENT EXPERIENCED POST-OPERATIVE BLEEDING AND REQUIRED HOSPITALIZATION IN THE ICU. THE SURGEON SAID HE NO LONGER WILL USE THE SYNCHROSEAL INSTRUMENT. INTUITIVE SURGICAL INC. (ISI) CONTACTED THE SURGEON WHO PERFORMED THIS PROCEDURE AND ADDITIONAL INFORMATION WAS OBTAINED ABOUT THE EVENT: THE PROCEDURE OCCURRED IN JUNE BUT THE EXACT DATE WAS NOT PROVIDED. THE PROCEDURE WAS PERFORMED ON A DA VINCI SI SYSTEM WITH AN UNKNOWN SERIAL NUMBER. THE SYNCHROSEAL INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NOTHING ABNORMAL FOUND. THE SURGEON REPORTED THAT THE SYNCHROSEAL INSTRUMENT WORKED FINE AND NO ERRORS WERE GENERATED FOR THE INSTRUMENT. THE TARGET ISSUE WAS THE PROSTATE PEDICLE. THE TARGET TISSUE WAS REPORTEDLY UNDER TENSION DURING THE SEALING AND CUTTING PROCESS. THE TARGET TISSUE WAS NOT A VESSEL GREATER THAN 5MM, HAD NO CALCIFICATION, AND NO PREVIOUS RADIATION OR CHEMOTHERAPY. THE SURGEON REPORTED THAT THEY OBSERVED TISSUE EFFECT DURING THE SEALING/SYNCH CYCLE. THE SURGEON SAID THE SYNCHROSEAL INSTRUMENT NEVER CAME INTO CONTACT WITH METAL OBJECTS SUCH AS STAPLES, SUTURES, AND CLIPS DURING THE PROCEDURE
cause not established2955842-2021-10764Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-08FDA MAUDEda Vinci Surgical System2955842-2022-12480da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: INTUITIVE SURGICAL INC. (ISI) BECAME AWARE OF A EUROPEAN UROLOGY OPEN SCIENCE ARTICLE TITLED, ¿SALVAGE VERSUS PRIMARY ROBOT-ASSISTED RADICAL PROSTATECTOMY: A PROPENSITY-MATCHED COMPARATIVE EFFECTIVENESS STUDY FROM A HIGH-VOLUME TERTIARY CENTRE¿ (NATHAN, A., FRICKER, M., ET AL., 2021). WITHIN THE CLINICAL JOURNAL ARTICLE, IT WAS CITED -ONE PATIENT SUFFERED FROM RECTAL INJURY WITH INTRAOPERATIVE PRIMARY REPAIR FOLLOWING WHOLE GLAND RADIOTHERAPY. ISI HAS MADE MULTIPLE FOLLOW-UP ATTEMPTS TO THE REACH OUT TO THE AUTHOR TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT. AT THIS TIME, IT WAS UNCONFIRMED AS TO WHETHER A DA VINCI SURGICAL SYSTEM WAS INVOLVED IN THE REPORTED EVENT AND THERE IS NO KNOWN ALLEGATION OF A MALFUNCTION OF A DA VINCI PRODUCT. MOREOVER, THERE IS INSUFFICIENT INFORMATION PROVIDED TO DETERMINE THAT AN INTUITIVE PRODUCT CAUSED OR CONTRIBUTED TO THE OPERATIVE COMPLICATION REFERENCED IN THE ARTICLE.
cause not established2955842-2022-12480Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-04FDA MAUDEda Vinci Surgical System2955842-2021-11769da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ON 22-NOV-2021, INTUITIVE SURGICAL, INC. (ISI) BECAME AWARE OF A INTERNATIONAL JOURNAL OF UROLOGY CASE REPORTS ARTICLE TITLED, ¿ENDOSCOPIC LASER TREATMENT FOR URINE LEAKAGE CAUSED BY AN ISOLATED CALYX AFTER ROBOT-ASSISTED PARTIAL NEPHRECTOMY¿ (INOUE, R., ISOYAMA, N., ET AL., 2021). WITHIN THE JOURNAL ARTICLE, A POST-OPERATIVE COMPLICATION INVOLVING A DA VINCI SURGICAL PROCEDURE WAS NOTED: "AN (B)(6) MAN UNDERWENT ROBOT-ASSISTED PARTIAL NEPHRECTOMY FOR THE TREATMENT OF RENAL CELL CARCINOMA (CT1BN0M0). POSTOPERATIVELY, URINE LEAKAGE WAS OBSERVED AND DID NOT IMPROVE WITH CONSERVATIVE MEASURES. RETROGRADE PYELOGRAPHY AND COMPUTED TOMOGRAPHY REVEALED THAT URINE LEAKAGE ORIGINATED FROM THE ISOLATED CALYX CAUSED BY INFUNDIBULAR STENOSIS. ENDOSCOPIC TREATMENT VIA THE TRANSURETHRAL APPROACH WAS SELECTED TO PRESERVE RENAL FUNCTION. URETEROSCOPY SHOWED THAT THE UPPER CALYX WAS COMPLETELY OBSTRUCTED BY THE SUTURES. THEREFORE, WE CUT THE SUTURE THREAD USING LASER, AND A URETERAL STENT WAS PLACED IN THE UPPER RENAL CALYX. FLUID DRAINAGE IMMEDIATELY DISAPPEARED AFTER THE PROCEDURE, AND THE PATIENT DID NOT LOSE RENAL FUNCTION." ISI HAS REACHED OUT TO THE AUTHOR TO OBTAIN ADDITIONAL INFORMATION BUT
cause not established2955842-2021-11769Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-03FDA MAUDEda Vinci Surgical System2955842-2021-10741da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, PIECES FROM THE CANNULA SEAL BROKE OFF AND FELL INSIDE THE PATIENT'S ABDOMEN. THE SURGEON WAS ABLE TO RETRIEVE ALL FRAGMENTS DURING THE SAME PROCEDURE. THE CANNULA SEAL IS AVAILABLE FOR RETURN TO INTUITIVE SURGICAL, INC. (ISI) FOR EVALUATION; HOWEVER, THE FRAGMENTS ARE NOT ABLE TO BE RETURNED. THE CUSTOMER REPLACED THE CANNULA SEAL WITH A BACK-UP ACCESSORY OF THE SAME KIND AND COMPLETED THE PROCEDURE WITH NO REPORTED INJURY. ISI MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10741Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-02FDA MAUDEda Vinci Surgical System2955842-2021-10765da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A DA VINCI ASSISTED PROSTATECTOMY SURGICAL PROCEDURE, THE PATIENT EXPERIENCED POST-OPERATIVE BLEEDING AND REQUIRED HOSPITALIZATION IN THE ICU. THE SURGEON SAID HE NO LONGER WILL USE THE SYNCHROSEAL INSTRUMENT. INTUITIVE SURGICAL INC. (ISI) CONTACTED THE SURGEON WHO PERFORMED THIS PROCEDURE AND ADDITIONAL INFORMATION WAS OBTAINED ABOUT THE EVENT: THE PROCEDURE OCCURRED IN JUNE BUT THE EXACT DATE WAS NOT PROVIDED. THE PROCEDURE WAS PERFORMED ON A DA VINCI SI SYSTEM WITH AN UNKNOWN SERIAL NUMBER. THE SYNCHROSEAL INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NOTHING ABNORMAL FOUND. THE SURGEON REPORTED THAT THE SYNCHROSEAL INSTRUMENT WORKED FINE AND NO ERRORS WERE GENERATED FOR THE INSTRUMENT. THE TARGET ISSUE WAS THE PROSTATE PEDICLE. THE TARGET TISSUE WAS REPORTEDLY UNDER TENSION DURING THE SEALING AND CUTTING PROCESS. THE TARGET TISSUE WAS NOT A VESSEL GREATER THAN 5MM, HAD NO CALCIFICATION, AND NO PREVIOUS RADIATION OR CHEMOTHERAPY. THE SURGEON REPORTED THAT THEY OBSERVED TISSUE EFFECT DURING THE SEALING/SYNCH CYCLE. THE SURGEON SAID THE SYNCHROSEAL INSTRUMENT NEVER CAME INTO CONTACT WITH METAL OBJECTS SUCH AS STAPLES, SUTURES, AND CLIPS DURING THE PROCEDURE
cause not established2955842-2021-10765Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-06-01FDA MAUDEda Vinci Surgical System2955842-2021-10597da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10597Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-31FDA MAUDEda Vinci Surgical System2955842-2021-10587da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PROSTATECTOMY SURGICAL PROCEDURE, THE MONOPOLAR CURVED SCISSORS (MCS) TIP COVER ACCESSORY SLIPPED OF THE MCS INSTRUMENT AND FELL INTO THE PATIENT. THE MCS TIP COVER ACCESSORY WAS REMOVED FROM THE PATIENT AND WAS REPORTEDLY DISCARDED. THE PROCEDURE WAS COMPLETED USING A BACKUP MCS TIP COVER ACCESSORY WITH NO REPORTED INJURY. THE INTUITIVE SURGICAL, INC. (ISI) CLINICAL TERRITORY ASSOCIATE (CTA) PROVIDED THE FOLLOWING INFORMATION: THE OPERATING ROOM NURSE WHO REPORTED THIS ISSUE TO THE CTA STATED SHE DOES NOT HAVE THE EVENT DATE INFORMATION. THE MCS INSTRUMENT AND MCS TIP COVER ACCESSORY WERE INSPECTED PRIOR TO USE. INSTALLATION OF TIP COVER ACCESSORY ON THE MCS INSTRUMENT WAS "EASIER THAN NORMAL." THE MCS TIP COVER ACCESSORY FELL INTO THE ABDOMEN AND THEY RETRIEVED IT WITH THE REMAINING INSTRUMENTS. INSTRUMENT REMOVAL TASK WAS BEING PERFORMED WHEN THE MCS TIP COVER ACCESSORY FELL INSIDE THE PATIENT. THE NURSE TOLD THE CTA THAT THE MCS TIP COVER ACCESSORY AND THE MCS WERE NOT BEEN DAMAGED. THE ORANGE SURFACE WAS NOT VISIBLE AFTER THE MCS TIP COVER ACCESSORY WAS INSTALLED. NO ELECTROLUBE OR OTHER LUBRICANT APPLIED TO THE MCS INSTRUMENT PR
cause not established2955842-2021-10587Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-30FDA MAUDEda Vinci Surgical System2955842-2021-10714da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE HARMONIC ACE WAS SUDDENLY BROKEN. THERE WAS NO REPORT OF FRAGMENT(S) FALLING INSIDE THE PATIENT. A SIMILAR BACKUP DA VINCI INSTRUMENT WAS USED. THE PROCEDURE WAS COMPLETED WITH NO REPORT OF PATIENT HARM, ADVERSE OUTCOME, OR INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE INSTRUMENT WAS USED FOR ABOUT ONE HOUR AND THE INSTRUMENT BLADE WAS BROKEN INSIDE THE PATIENT. THE SURGEON REMOVED THE FRAGMENT BY USING A GRASPER, DURING THE SAME PROCEDURE. THE INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NO DAMAGE FOUND. DURING A DA VINCI-ASSISTED THYROIDECTOMY SURGICAL PROCEDURE, THE INSTRUMENT BROKE WHILE IT WAS BEING USED FOR DISSECTING TISSUE. ALL THE FRAGMENTS WERE RETRIEVED UPON VISUAL INSPECTION. IT WAS UNKNOWN WHAT CAUSED THE BREAKAGE AS THE INSTRUMENT DID NOT COLLIDE WITH ANY HARD MATERIALS OR OTHER INSTRUMENTS. THERE WAS NO PATIENT INJURY. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT. THE FRAGMENT(S) DID NOT FALL INSIDE THE PATIENT DURING AN INSTRUMENT TIP OR ACCESSORY COLLISION. THE INSTRUMENT WAS NO
cause not established2955842-2021-10714Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-27FDA MAUDEda Vinci Surgical System2955842-2021-10726da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED GASTRIC BYPASS SURGICAL PROCEDURE, A SMALL DISC FELL OFF OF THE SYNCHROSEAL INSTRUMENT AND INTO THE ABDOMEN OF THE PATIENT. THE SMALL DISC WAS REMOVED DURING THE SAME PROCEDURE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER ON (B)(6) 2021 AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE FRAGMENT WAS RETRIEVED VIA ROBOTIC INSTRUMENT. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT DURING THE SURGICAL PROCEDURE AND WAS UNSURE OF THE CAUSE OF THE ISSUE. THE FOLLOWING WAS INFORMATION WAS REQUESTED, BUT WAS UNKNOWN: WHAT SURGICAL TASK WAS BEING PERFORMED AT THE TIME OF THE ISSUE, HOW LONG THE INSTRUMENT HAD BEEN IN USE AT THE TIME OF THE ISSUE, IF THERE WERE ANY COLLISIONS, IF THE INSTRUMENT WAS REMOVED THROUGH THE CANNULA PRIOR TO THE ISSUE, AND IF THERE WAS ANY OTHER DAMAGE TO THE INSTRUMENT OR THE CANNULA ONCE THE INSTRUMENT HAD BEEN REMOVED. THE INSTRUMENT IS AVAILABLE FOR RETURN TO ISI. THERE ARE PHOTOGRAPHIC IMAGES AVAILABLE OF THE INSTRUMENT AND THE FRAGMENT. PATIENT-RE
cause not established2955842-2021-10726Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-21FDA MAUDEda Vinci Surgical System2955842-2021-10922da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE MAIN MACHINE OF THE ULTRASONIC KNIFE WAS REPORTING THAT THE PRESSURE OF THE KNIFE HEAD WAS TOO LARGE. DURING THE OPERATION, THE PATIENT SUFFERED FROM "A LOT OF BLEEDING." THE NURSE PULLED OUT THE ULTRASONIC KNIFE FOR RE-TESTING, AND THE MAIN MACHINE OF THE ULTRASONIC KNIFE SUGGESTED THAT THE INSTRUMENT SHOULD BE REPLACED. THERE WAS NO REPORT OF ANY FRAGMENT(S) FALLING INSIDE THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A BACKUP DA VINCI INSTRUMENT OF THE SAME KIND, AND THERE WAS NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10922Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-21FDA MAUDEda Vinci Surgical System2955842-2021-10920da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE MAIN MACHINE OF THE ULTRASONIC KNIFE WAS REPORTING THAT THE PRESSURE OF THE KNIFE HEAD WAS TOO LARGE. DURING THE OPERATION, THE PATIENT SUFFERED FROM "A LOT OF BLEEDING." THE NURSE PULLED OUT THE ULTRASONIC KNIFE FOR RE-TESTING, AND THE MAIN MACHINE OF THE ULTRASONIC KNIFE SUGGESTED THAT THE INSTRUMENT SHOULD BE REPLACED. THERE WAS NO REPORT OF ANY FRAGMENT(S) FALLING INSIDE THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A BACKUP DA VINCI INSTRUMENT OF THE SAME KIND, AND THERE WAS NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10920Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-18FDA MAUDEda Vinci Surgical System2955842-2021-10665da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10665Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-18FDA MAUDEda Vinci Surgical System2955842-2021-10775da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PROSTATECTOMY PROCEDURE, THE USER OBSERVED THAT "THE PART THAT HOLDS THE SYNCHROSEAL INSTRUMENT JAW COVER WAS DAMAGED" AND A FRAGMENT FELL INSIDE THE PATIENT. THE BROKEN FRAGMENT WAS RETRIEVED DURING THE SAME SURGICAL PROCEDURE. THE USER NOTED THAT THE INSTRUMENT WAS NOT INVOLVED IN ANY KNOWN INSTRUMENT COLLISION. THE INSTRUMENT WAS REMOVED AND REPLACED TO THE BACKUP. THE USER COMPLETED THE PROCEDURE WITH NO FURTHER ISSUE. NO KNOWN IMPACT OR PATIENT CONSEQUENCE WAS REPORTED. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE SITE AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION REGARDING THE REPORTED EVENT: THE INSTRUMENT WAS INSPECTED PRIOR TO USE AND FOUND NO ISSUE. INSTRUMENT OPERATED WITH NO FUNCTIONAL ISSUE. SURGEON ALLEGES NO INCIDENT OF INSTRUMENT COLLISION. THE INSTRUMENT WAS IN USE FOR APPROXIMATELY AN HOUR. THE FALLEN FRAGMENT WAS REMOVED THROUGH THE ASSIST PORT. NO ADDITIONAL SURGICAL PROCEDURE WAS REQUIRED TO REMOVE THE FRAGMENT. STANDARD POST-OPERATIVE TESTS WERE PERFORMED AND CONFIRMED NO RETAINED FRAGMENT.
cause not established2955842-2021-10775Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-14FDA MAUDEda Vinci Surgical System2955842-2021-10637da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10637Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-14FDA MAUDEda Vinci Surgical SystemMW5101444da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DA VINCI XI ROBOT EXPERIENCED NONRECOVERABLE FAULT ERROR CODE 307 DURING MID PROCEDURE. INSTRUMENT ARMS WERE LEFT IN PATIENT. REP ADVISED TOTAL SYSTEM SHUTDOWN AND RESTART. SYSTEM SHUT DOWN AND RESTARTED 3 TIMES, NONRECOVERABLE FAULT RESULTED EACH TIME. INSTRUMENTS AND DA VINCI REMOVED MANUALLY AS RESULT OF FAILURE. PROCEDURE CONTINUED THORACOSCOPICALLY. AFTER TROUBLESHOOTING THIS ISSUE, DA VINCI REP DETERMINED THE TITLE PRO CABLE CONNECTED TO THE STORZ CAMERA SYSTEM FRIED THE TITLE PRO INPUT BOX IN THE DA VINCI ROBOT, RESULTING IN NONRECOVERABLE FAULT ERROR CODE 307. VENDOR CAME ONSITE 5/16 AND REPAIRED UNIT. UNIT RETURNED TO SERVICE. VIDEO OUTPUT ON VISION TOWER WAS REPLACED. COMPOSITE VIDEO COMPONENT PROTRUDES FROM EQUIPMENT LEADING TO HIGHER LIKELIHOOD OF DAMAGE. FDA SAFETY REPORT ID # (B)(4).
cause not establishedMW5101444Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-11FDA MAUDEda Vinci Surgical System2955842-2021-10630da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10630Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-05-04FDA MAUDEda Vinci Surgical System2955842-2021-10592da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED HIATAL HERNIA-PARAESOPHAGEAL SURGICAL PROCEDURE, PART OF THE SHEAR OF THE HARMONIC ACE INSTRUMENT BROKE AND FELL INTO THE PATIENT. THE PIECE WAS RETRIEVED FROM THE ABDOMEN. THE CUSTOMER OPENED ANOTHER HARMONIC ACE INSTRUMENT TO COMPLETE THE CASE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10592Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-30FDA MAUDEda Vinci Surgical System2955842-2021-10578da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PANCREATECTOMY SURGICAL PROCEDURE, A PLASTIC PART FROM THE HARMONIC ACE INSTRUMENT BROKE AND FELL INSIDE THE PATIENT. THE FRAGMENT WAS RETRIEVED AND A BACKUP INSTRUMENT WAS USED TO CONTINUE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE CUSTOMER RETRIEVED FRAGMENTS AND CONFIRMED BY VISUAL INSPECTION THAT ALL BROKEN PIECES WERE RETRIEVED. THERE WAS NO ADDITIONAL PROCEDURE REQUIRED TO REMOVE THE FRAGMENTS. THERE WERE NO POST-OPERATIVE TESTS PERFORMED TO CHECK FOR REMAINING FRAGMENTS. THE INSTRUMENT WAS IN USE FOR LESS THAN 1 HOUR PRIOR TO THE ISSUE. THE INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NO ISSUES NOTED. THE SURGEON WAS REMOVING THE INSTRUMENT WHEN THE DEVICE FRAGMENT FELL INSIDE THE PATIENT. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT. THE INSTRUMENT DID NOT COLLIDE WITH ANY OTHER INSTRUMENTS OR OTHER HARD MATERIAL DURING THE SURGICAL PROCEDURE. THE INSTRUMENT WAS NEVER REMOVED PRIOR TO THE EVENT. THE SURGICAL STAFF DID NOT FEEL ANY RESISTANCE UPON THE FINAL REMOVA
cause not established2955842-2021-10578Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-28FDA MAUDEda Vinci Surgical System2955842-2021-11858da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED LIVER RESECTION SURGICAL PROCEDURE, THE BLADE OF THE HARMONIC ACE INSTRUMENT BROKE OFF AND FELL INTO THE PATIENT. THE PIECE WAS RETRIEVED AND NO PARTS REMAINED IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION, HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF DATE OF THIS REPORT REGARDING THIS EVENT.
cause not established2955842-2021-11858Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-26FDA MAUDEda Vinci Surgical System2955842-2021-10550da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10550Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-23FDA MAUDEda Vinci Surgical System2955842-2021-10570da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PARTIAL NEPHRECTOMY SURGICAL PROCEDURE, THE MONOPOLAR CURVED SCISSORS TIP COVER ACCESSORY FELL INTO THE SITUS. THE TIP COVER ACCESSORY WAS RETRIEVED DURING THE SAME PROCEDURE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) ATTEMPTED TO FOLLOW-UP WITH THE CUSTOMER TO OBTAIN ADDITIONAL DETAILS RELATED TO THE EVENT. HOWEVER, AS OF THE DATE OF THIS REPORT, NO FURTHER INFORMATION HAS BEEN RECEIVED.
cause not established2955842-2021-10570Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-23FDA MAUDEda Vinci Surgical System2955842-2021-10544da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PROSTATECTOMY SURGICAL PROCEDURE THE SYNCHROSEAL INSTRUMENT JAW HINGE PIN, END PIECE, FELL OFF THE INSTRUMENT INTO THE PATIENT. THE SURGEON RETRIEVED THE PIECE WITH A BACKUP INSTRUMENT AND CONTINUED THE PROCEDURE. NO OTHER PIECES WERE OBSERVED TO BE MISSING FROM THE INSTRUMENT. THE INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SUPPORT ENGINEER (TSE) ADVISED THE CALLER TO PROMPT THE CUSTOMER TO RETURN THE INSTRUMENT FOR FAILURE ANALYSIS. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. ISI MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10544Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-22FDA MAUDEda Vinci Surgical System2955842-2021-10608da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10608Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-21FDA MAUDEda Vinci Surgical System2955842-2021-10528da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED BENIGN HYSTERECTOMY SURGICAL PROCEDURE, IT WAS NOTED THAT ONE OF THE PADS ON THE HARMONIC SCALPEL FELL OFF INTO THE PATIENT. THE CUSTOMER INFORMED THE INTUITIVE SURGICAL, INC. (ISI) CLINICAL SALES REPRESENTATIVE (CSR) THE ISSUE HAD OCCURRED AND THE CUSTOMER RETRIEVED THE GREY INSTRUMENT TIP PAD WITH NO ISSUES TO THE PATIENT. IT WAS NOTED THE CUSTOMER DISCARDED THE INSTRUMENT. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. ISI FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE CLINICIAN INFORMED THE INSTRUMENT WAS INSPECTED PRIOR TO USE. PRIOR TO THE FRAGMENT FALLING, THE INSTRUMENT HAD BEEN IN USE FOR ABOUT 45 60 MINUTES. AT THE TIME OF THE REPORTED ISSUE, THE CLINICIAN NOTED THAT THE SURGEON WAS PERFORMING AN EXCISION OF FIBROIDS AND STATED THE HARMONIC INSTRUMENT AND TENACULUM INSTRUMENT COLLIDED. THE SURGEON DID NOT NOTICE AN ISSUE WITH THE INSTRUMENT FUNCTIONALITY DURING THE CASE. IT WAS NOTED THE FRAGMENT FELL OFF INTO THE PATIENT IN THE MIDDLE OF THE CASE AND DID NOT OCCUR DURING AN INSTRUMENT COLLISION. THE WHITE TIP OF THE HARMONIC INSTRUMENT WAS RETRIEVED IN ONE PIECE WITH A G
cause not established2955842-2021-10528Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-20FDA MAUDEda Vinci Surgical System2955842-2021-10645da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10645Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-19FDA MAUDEda Vinci Surgical System2955842-2021-10518da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED MALIGNANT HYSTERECTOMY SURGICAL PROCEDURE, THE SYNCHROSEAL INSTRUMENT WAS FOUND TO HAVE THE BUTTON FELL OFF. THE BUTTON WAS IN A CUP. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: IT WAS CONFIRMED THAT THE BUTTON SIMPLY FELL OFF AND WAS DISCOVERED WITHIN THE PATIENT. THE INSTRUMENT WAS INSPECTED PRIOR TO USE. THE FRAGMENT WAS LIKELY RETRIEVED WITH A ROBOTIC/LAP INSTRUMENT DURING THE CASE. NO POST-OPERATIVE TESTS LIKE AN X-RAY OR ULTRASOUND WERE PERFORMED TO CHECK FOR REMAINING FRAGMENTS. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT NOR ANY OTHER DAMAGE TO THE INSTRUMENT AFTER THE EVENT OCCURRED. THE WRIST WAS NOT STRAIGHTENED PRIOR TO REMOVAL BUT WAS STRAIGHTENED UPON FINAL REMOVAL OF THE INSTRUMENT. NO PATIENT INJURY WAS IDENTIFIED. THE PART L90200818-0262 WAS USED ON (B)(6) 2021.
cause not established2955842-2021-10518Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-19FDA MAUDEda Vinci Surgical System2955842-2021-10509da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SPLENECTOMY PROCEDURE, BLEEDING OCCURRED. THE SURGEON REPORTED THAT HE THINKS HE GRABBED A VEIN WHICH CAUSED THE BLEEDING. THE SITE GAVE THE PATIENT A BLOOD TRANSFUSION AND CONVERTED TO OPEN SURGERY. THE SURGEON REPORTED TWO DAYS AFTER THE PROCEDURE THAT THE PATIENT WAS DOING FINE. THE SURGEON REPORTED THAT HE DOES NOT BELIEVE AN INTUITIVE SURGICAL INC. (ISI) PRODUCT CAUSED OR CONTRIBUTED TO THE REPORTED INJURY. FOLLOW-UP: ON 04/22/2021, INTUITIVE SURGICAL INC. (ISI) CONTACTED THE CONSOLE SURGEON OF THE PROCEDURE AND ADDITIONAL INFORMATION WAS OBTAINED ABOUT THE EVENT: THE BLEEDING EVENT OCCURRED WHILE TAKING THE SPLENIC MINOR ATTACHMENT WITH THE SYNCHROSEAL INSTRUMENT. THE SURGEON SAID WHILE HE WAS SEALING TISSUE BLOOD STARTED FLOWING FROM IT. THE SURGEON CLARIFIED THAT THE BLOOD APPEARED WHILE THE SYNCHROSEAL INSTRUMENT WAS SEALING WITH ENERGY. THE SURGEON GRASPED THE BLEEDING VESSEL AT THE INFLOW SIDE, BUT THE BLOOD VOLUME INCREASED; THE PROCEDURE WAS THEN CONVERTED TO OPEN TO CONTROL THE BLEEDING VESSEL WITH SUTURES. THE SURGEON SAID THE VESSEL WAS NOT LARGER THAN 5MM AND THAT THE SYNCHROSEAL WAS WORKING FINE DURING THE WHOLE PROC
cause not established2955842-2021-10509Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Death reported2021-04-19FDA MAUDEda Vinci Surgical SystemMW5110378da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE PATIENT HAD A MILD HERNIA THAT NEEDED REPAIR. IT WAS DONE ROBOTICALLY USING THE DAVINCI SYSTEM. THE PATIENT HAD A PUNCTURED ARTERY AND A LACERATED BOWEL FROM SURGICAL ERRORS DURING THE PROCEDURE. THERE WAS EXTENSIVE INTERNAL BLEEDING. THE PATIENT BECAME SEPTIC AND WITHIN THREE DAYS WAS DEAD. THE PATIENT WAS HEALTHY WHEN HE WALKED IN EVEN THOUGH HE WAS AN OLDER PATIENT. THE PATIENT WENT TO THE HOSPITAL WITH UPPER ABDOMINAL PAIN. IT WAS DETERMINED HE HAD A HERNIA AND HE WAS SENT TO A DOCTOR TO HAVE IT REPAIRED. FDA SAFETY REPORT ID # (B)(4).
cause not establishedMW5110378Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-18FDA MAUDEda Vinci Surgical System2955842-2021-10574da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE MASTER KNIFE WAS CUTTING THE LIVER, AND THE ULTRASONIC KNIFE HEAD SUDDENLY BROKE OFF WITHOUT ANY HINT. FORTUNATELY, THE BROKEN KNIFE HEAD WAS PICKED OUT. THE FRAGMENT WAS RETRIEVED DURING THE OPERATION. THE PROCEDURE WAS COMPLETED WITH A BACKUP DA VINCI INSTRUMENT OF THE SAME KIND, AND THERE WAS NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE CUSTOMER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE INSTRUMENT WAS INSPECTED PRIOR TO USE. THE INSTRUMENT WAS USED FOR APPROXIMATELY ONE HOUR PRIOR TO THE BREAKAGE. THE SURGEON HAD NO ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT DURING THE PROCEDURE. THE SURGEON HAD NO ISSUES WITH REMOVING THE INSTRUMENT FROM THE ARM PRIOR TO THE BREAKAGE. THERE WAS NO REPORT OF COLLISION WITH ANY OTHER INSTRUMENTS OR OTHER HARD MATERIAL. ALL FRAGMENT(S) WERE RETRIEVED WITH THE ENDOSCOPIC INSTRUMENT DURING THE SAME PROCEDURE. NO SURGICAL PROCEDURES WERE REQUIRED TO REMOVE THE FRAGMENT. NO POST-OPERATIVE TESTS WERE PERFORMED TO CHECK FOR REMAINING FRAGMENTS. NO INFORMATION WAS PROVIDED PERTAINING TO IF THE PATIENT HAS RETURNED TO THE HOSPITAL DUE TO PO
cause not established2955842-2021-10574Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-15FDA MAUDEda Vinci Surgical System2955842-2021-10513da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10513Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-15FDA MAUDEda Vinci Surgical System2955842-2021-10504da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10504Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-12FDA MAUDEda Vinci Surgical System2955842-2021-10487da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PARTIAL NEPHRECTOMY SURGICAL PROCEDURE, AFTER INSERTING THE SYNCHROSEAL INSTRUMENT INTO THE BODY CAVITY IMMEDIATELY AFTER THE START OF SURGERY, THE PART WHICH HOLDS THE JAW COVER FELL INTO THE BODY WHEN THE WRIST WAS MOVED. THE PART WAS REPORTEDLY IMMEDIATELY RETRIEVED. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE REPORTER ON 15-APRIL-2021 AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION RELATED TO THE EVENT. THE FRAGMENT WAS RETRIEVED BY USING THE SYNCHROSEAL INSTRUMENT. NO POST-OPERATIVE TESTS WERE REQUIRED AS IT WAS VISUALLY CONFIRMED THAT NO OTHER FRAGMENTS REMAINED INSIDE THE PATIENT. IT WAS UNKNOWN WHETHER THE INSTRUMENT WAS INSPECTED PRIOR TO USE, BUT REPORTEDLY THE INSTRUMENT DID COLLIDE WITH OTHER INSTRUMENTS OR OTHER HARD MATERIAL DURING THE PROCEDURE. THE INSTRUMENT WAS NOT REMOVED INTRAOPERATIVELY. UPON FINAL REMOVAL OF THE INSTRUMENT, THE WRIST WAS STRAIGHTENED THERE WAS NO RESISTANCE FELT UPON REMOVAL THROUGH THE CANNULA, AND THERE WAS NO DAMAGE NOTED TO EITHER THE INSTRUMENT OR THE CANNULA. IT WAS ALSO CONFIRMED THAT THERE WAS NO PATIENT INJURY THAT
cause not established2955842-2021-10487Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-12FDA MAUDEda Vinci Surgical System2955842-2021-10507da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE BLADE OF THE HARMONIC ACE INSTRUMENT BROKE AND FELL INSIDE THE PATIENT. THE FRAGMENT WAS RETRIEVED AND A BACKUP INSTRUMENT OF THE SAME KIND WAS USED TO CONTINUE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE CUSTOMER RETRIEVED THE WHITE POWDER FRAGMENTS BY SUCTION. THERE WAS NO ADDITIONAL PROCEDURE REQUIRED TO REMOVE THE FRAGMENT. NO POST-OPERATIVE TESTS WERE PERFORMED TO CHECK FOR REMAINING FRAGMENTS. THE INSTRUMENT WAS IN USE FOR LESS THAN 5 MINUTES PRIOR TO THE ISSUE. THE INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NO ISSUES NOTED. THE SURGEON WAS DISSECTING TISSUES WHEN THE DEVICE FRAGMENTS FELL INSIDE THE PATIENT. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT. THE INSTRUMENT DID NOT COLLIDE WITH ANY OTHER INSTRUMENTS OR OTHER HARD MATERIAL DURING THE SURGICAL PROCEDURE. THE INSTRUMENT WAS NEVER REMOVED PRIOR TO THE EVENT. THE SURGICAL STAFF DID NOT FEEL ANY RESISTANCE UPON FINAL REMOVAL OF THE INSTRUMENT THROUGH THE CANNULA OR TO THE INSTRUMENT A
cause not established2955842-2021-10507Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-09FDA MAUDEda Vinci Surgical System2955842-2022-12646da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS INITIALLY REPORTED THAT DURING A DA VINCI-ASSISTED CHOLECYSTECTOMY PROCEDURE, THE ¿ENERGY BOX WAS NOT WORKING¿. THE CUSTOMER CONTACTED AN INTUITIVE SURGICAL, INC. (ISI) CLINICAL SALES REPRESENTATIVE (CSR) WHO THEN REACHED OUT TO AN ISI TECHNICAL SUPPORT ENGINEER (TSE). THE CUSTOMER HAD TRIED TO RESEAT THE BIPOLAR ENERGY CABLE MULTIPLE TIMES, TRIED DIFFERENT ENERGY CABLES, AND TRIED TO RESEAT THE INSTRUMENTS MULTIPLE TIMES; ALL WITH NO CHANGE. A MESSAGE HAD PRESENTED ON THE VISION SIDE CART (VSC) TOUCHSCREEN (TS) MONITOR STATING, "VIO DV IS NOT CONNECTED" AND A RED QUESTION MARK DISPLAYED WITH AN INCOMPATIBLE INSTRUMENT MESSAGE ON THE ERBE GENERATOR. THE TSE CHECKED THE LIVE SYSTEM LOGS AND DID NOT SEE ANY RELEVANT ERRORS PRESENT IN THE LOGS. THE TSE HAD CUSTOMER RESEAT THE POWER CABLE ON THE BACK OF THE ERBE AND CHECK ERBE CONNECTIONS, BUT ALL FELT SECURE. THE TSE WALKED THE CUSTOMER THROUGH A SYSTEM POWER CYCLE AND THE CUSTOMER MOVED THE ERBE POWER CABLE TO A DIFFERENT OUTLET. THE CUSTOMER THEN POWER CYCLED THE ERBE GENERATOR. THE SYSTEM THEN POWERED ON WITH MONOPOLAR AND BIPOLAR ENERGY WORKING NORMALLY. IT WAS REPORTED THAT THE PATIENT EXPERIENCED ¿A LITTLE BLEEDING DURING
cause not established2955842-2022-12646Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-06FDA MAUDEda Vinci Surgical System2955842-2021-10464da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10464Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-01FDA MAUDEda Vinci Surgical System2955842-2021-10454da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10454Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-04-01FDA MAUDEda Vinci Surgical System2955842-2021-10453da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10453Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-30FDA MAUDEda Vinci Surgical System2955842-2021-10466da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10466Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-25FDA MAUDEda Vinci Surgical System2955842-2022-12332da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A PROSPECTIVE IRIS STUDY ROBOTIC PARTIAL NEPHRECTOMY ON (B)(6) 2021, THE PATIENT PRESENTED WITH PRE-SYNCOPAL SYMPTOMS ON (B)(6) 2021. THE PATIENT¿S ¿HEMATOCRIT (HCT) DROPPED FROM 41 TO 25, COMPUTED TOMOGRAPHY (CT) A/P¿ INDICATING A CONCERN FOR BLEEDING AT THE SURGICAL SITE. THE PATIENT UNDERWENT ¿IR COIL EMBOLIZATION OF THE RIGHT RENAL ARTERY PSEUDOANEURYSM¿ (B)(6) 2021 AND TOLERATED THE PROCEDURE WITH NO IMMEDIATE COMPLICATIONS. THE PATIENT WAS ADMITTED TO THE HOSPITAL THEN DISCHARGED ON (B)(6) 2021. ON (B)(6) 2021, INTUITIVE SURGICAL, INC. (ISI) OBTAINED THE FOLLOWING ADDITIONAL INFORMATION REGARDING THE REPORTED EVENT: IT WAS CONFIRMED THAT THERE WERE NO REPORTED INTRA-OPERATIVE COMPLICATIONS AND NO ISSUES WITH IRIS MEDICAL IMAGING. DUE TO THE POST-PROCEDURE COMPLICATIONS, THE PATIENT WAS ADMINISTERED AN UNSPECIFIED AMOUNT OF BLOOD BY TRANSFUSION. IT WAS CONFIRMED THAT THE SURGEON VERBALLY STATED, AND DOCUMENTED IN THE ELECTRONIC DOCUMENTATION (EDC), THAT THERE IS NO ALLEGATION OF A MALFUNCTION OF A DA VINCI PRODUCT AND NO ALLEGED CAUSAL RELATIONSHIP BETWEEN THE IRIS STUDY AND THE PATIENT¿S POST-OPERATIVE BLEEDING COMPLICATION AND SUBSEQUENT BLOOD TRAN
cause not established2955842-2022-12332Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-23FDA MAUDEda Vinci Surgical System2955842-2021-10296da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED LOW ANTERIOR RESECTION PROCEDURE ON AN UNKNOWN EVENT DATE, THE MONOPOLAR CURVED SCISSOR (MCS) INSTRUMENT TIP COVER ACCESSORY FELL INSIDE THE PATIENT WHILE THE CUSTOMER WAS REMOVING THE INSTRUMENT THROUGH THE TROCAR. THE ITEM WAS RETRIEVED DURING THE SAME PROCEDURE. THE PROCEDURE WAS COMPLETED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10296Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-15FDA MAUDEda Vinci Surgical System2955842-2021-10505da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE HARMONIC ACE BROKE APART. PIECES FELL INSIDE THE PATIENT BUT THE SURGEON WAS ABLE TO RETRIEVE ALL OF THE PIECES. THE SITE STATED THAT THEY HAD THREE DIFFERENT OPERATING ROOM STAFF CONFIRM THAT ALL OF THE PIECES WERE REMOVED FROM THE PATIENT, MATCHED UP, AND NO SMALL FRAGMENTS BROKE OFF. NO POST-OP X-RAY WAS COMPLETED. THEY REPLACED THE HARMONIC INSTRUMENT WITH A DIFFERENT HARMONIC TO COMPLETE THE PROCEDURE. INTUITIVE SURGICAL INC. (ISI) MADE MULTIPLE FOLLOW-UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION. HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF THE DATE OF THIS REPORT.
cause not established2955842-2021-10505Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-11FDA MAUDEda Vinci Surgical System2955842-2021-10357da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS INITIALLY REPORTED THAT DURING A DA VINCI-ASSISTED PARTIAL RETROPERITONEAL NEPHRECTOMY PROCEDURE, A TIP COVER ¿SPLIT¿ ON THE MONOPOLAR CURVED SCISSORS (MCS) INSTRUMENT WHICH RESULTED IN AN, ¿INVERTED BLEED FROM AN ARTERY¿. TO RESOLVE THE ISSUE, THE SURGEON CONVERTED THE PROCEDURE TO OPEN SURGERY TO CONTROL THE BLEEDING. THE PATIENT WAS REPORTED AS BEING IN STABLE CONDITION FOLLOWING THE PROCEDURE. ON 15-MAR-2021, INTUITIVE SURGICAL, INC. (ISI) OBTAINED THE FOLLOWING ADDITIONAL INFORMATION REGARDING THE REPORTED EVENT: DURING A DA VINCI-ASSISTED PARTIAL RETROPERITONEAL NEPHRECTOMY PROCEDURE, AN ¿MCS TIP COVER WAS TORN AT SOME POINT DURING THE PROCEDURE AND NOBODY NOTICED IT¿. THE SITE BELIEVED THAT THERE WAS ARCING THAT CAUSED, ¿EXCESSIVE BLEEDING TO AN UNSPECIFIED ARTERY WHICH REQUIRED A BLOOD TRANSFUSION¿, UNKNOWN AMOUNT, AND THE PROCEDURE CONVERTED TO OPEN SURGERY. THE SURGEON DID NOT KNOW WHERE THE BLEEDING WAS COMING FROM AND DID NOT KNOW WHAT CAUSED THE BLEEDING. THE DA VINCI-ASSISTED PARTIAL NEPHRECTOMY PROCEDURE CONVERTED TO OPEN RADICAL NEPHRECTOMY SURGERY. THE OPEN PROCEDURE COMPLETED. THE PATIENT WAS DESCRIBED AS DOING WELL POST-OPERATIVELY. INTUITIVE SURGICAL, INC
cause not established2955842-2021-10357Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-09FDA MAUDEda Vinci Surgical System2955842-2021-10365da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10365Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-09FDA MAUDEda Vinci Surgical System2955842-2022-12576da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER COMPLETION OF A DA VINCI-ASSISTED TOTAL BENIGN HYSTERECTOMY PROCEDURE, THERE WAS A ¿PORT SITE TROCAR BURN¿. THE ISSUE WAS FOUND WHEN UNDOCKING THE SYSTEM ARM AND THE SURGEON STARTED TO ¿SUTURE-CLOSE¿ THE PORT SITE. THE BURN WAS IN THE SHAPE OF A CIRCLE ABOUT 2MM WIDE ALL AROUND THE PORT SITE. THE SURGEON EXCISED THE BURNT SKIN AND SUTURED THE PORT SITE. THE PROCEDURE WAS REPORTEDLY COMPLETED ROBOTICALLY. ON (B)(6) 2021, INTUITIVE SURGICAL, INC. (ISI) OBTAINED THE FOLLOWING ADDITIONAL INFORMATION REGARDING THE REPORTED EVENT: THE SURGEON REPORTEDLY DID NOT KNOW WHAT CAUSED THE ISSUE TO OCCUR, BUT THE SURGEON DID STATE THAT ALL INSTRUMENTS WORKED AS EXPECTED AND AS INTENDED BUT THEN NOTICED THE PORT SITE TISSUE BURN AND COULD NOT EXPLAIN WHAT CAUSED IT. THE PORT IN WHICH THE SYNCHROSEAL (SS) INSTRUMENT WAS USED WAS UNKNOWN. IT WAS ALSO UNKNOWN WHICH PORT SITE WAS INVOLVED WITH THE EVENT. WHILE THE SEVERITY OF THE PORT SITE BURN WAS UNKNOWN, THE BURN WAS DESCRIBED AS ¿A DARK CIRCLE OF BURNT SKIN AROUND ONLY ONE OF THE PORT SITES AND IT WAS ABOUT 2MM WIDE¿ FOR WHICH THE SURGEON ¿EXCISED THE BURNT SKIN AND SUTURED THE PORT SITE AS USUAL¿. THE PROCEDURE WAS COM
cause not established2955842-2022-12576Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-05FDA MAUDEda Vinci Surgical System2955842-2021-10347da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: REFER TO H10/H11 FOR FOLLOW-UP INFORMATION.
cause not established2955842-2021-10347Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2021-03-02FDA MAUDEda Vinci Surgical System2955842-2021-10325da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE HARMONIC ACE INSTRUMENT WAS DAMAGED AND NON-FUNCTIONAL AFTER ONE HOUR OF USE. THERE WAS ¿DEBRIS¿ LEFT IN THE PATIENT. THE ¿DEBRIS¿ WAS RETRIEVED IN THE SAME PROCEDURE AND THE HARMONIC ACE WAS REMOVED. THERE WAS NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) MADE MULTIPLE FOLLOW UP ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION, HOWEVER, NO FURTHER DETAILS HAVE BEEN RECEIVED AS OF DATE OF THIS REPORT.
cause not established2955842-2021-10325Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗