Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
2 records match for Intuitive Surgical, Inc.
2 death reports20231 registryClear
Narrow it down
What happened
Country
Year
Death reported2023-10-21FDA MAUDE2955842-2023-19485da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DURING INVESTIGATION OF AN UNRELATED EVENT, A SURGEON NOTIFIED AN INTUITIVE SURGICAL, INC. (ISI) CLINICAL SALES REPRESENTATIVE THAT THE COUNTY MEDICAL EXAMINER (ME), WHILE PROVIDING AUTOPSY RESULTS FOR THE UNRELATED EVENT, "RECALLED TWO PREVIOUS PATIENT DEATHS CAUSED BY ROBOTIC STAPLE LINES NOT HOLDING UP ON ARTERIES AND CAUSING BLEEDING." THE ME RECALLED THAT ONE PATIENT HAD RECEIVED A ROBOTIC-ASSISTED PROSTATECTOMY, AND THE OTHER PATIENT RECEIVED A ROBOTIC-ASSISTED SPLENECTOMY. THERE WAS NO ADDITIONAL INFORMATION EXCHANGED, OTHER THAN THE EVENTS OCCURRED AT DIFFERENT HOSPITALS. THE MEDICAL EXAMINERS OFFICE WAS CONTACTED TO REQUEST ADDITIONAL INFORMATION. THE ME ASSISTANT STATED THEY WOULD REVIEW PREVIOUS CASES TO DETERMINE IF THERE WERE ANY SIMILAR CASES. UPON FOLLOW UP, THE ME ASSISTANT REPORTED FINDING A PROSTATECTOMY CASE FROM 2015, AND THE ONLY INFORMATION THEY COULD SHARE WAS THE DATE OF DEATH AND HOSPITAL WHERE THE PROCEDURE WAS PERFORMED. THERE WERE NO SIMILAR SPLENECTOMY CASES FOUND IN THE MEDICAL EXAMINERS RECORDS. THE MEDICAL EXAMINER DECLINED TO PROVIDE ANY FURTHER INFORMATION AND DESCRIBED THE CONVERSATION AS A BRIEF COLLEAGUE-TO-COLLEAGUE OBSERVATION. NO ADDITIONAL I
cause not established2955842-2023-19485Intuitive Surgical, Inc.Read the record ↗Death reported2023-10-11FDA MAUDE2955842-2023-19914da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI ASSISTED HIATAL HERNIA REPAIR, THE INFERIOR VENA CAVA (IVC) WAS INJURED. THE SURGEON REPORTED THAT THE INJURY OCCURRED DUE TO ATYPICAL ANATOMY. WHILE USING THE HARMONIC ACE SHEARS TO DIVIDE THE GASTROHEPATIC LIGAMENT, A MALPOSITION OF THE IVC RELATIVE TO ITS NORMAL POSITION WAS ENCOUNTERED. THE IVC WAS TENSELY PULLED ACROSS THE DIAPHRAGM AND UNRECOGNIZED AS IT WAS TUCKED RIGHT BEHIND THE GASTROHEPATIC LIGAMENT. THE SURGEON BELIEVES THE SIDEWALL OF THE IVC WAS UNKNOWINGLY GRASPED IN THE INSTRUMENT JAWS WHILE DIVIDING THE LIGAMENT. THE PROCEDURE WAS CONVERTED TO OPEN TO ADDRESS THE INJURY, BUT THE PATIENT EXPIRED. THERE WAS NO REPORTED INTUITIVE SURGICAL, INC. (ISI) PRODUCT MALFUNCTION.
cause not established2955842-2023-19914Intuitive Surgical, Inc.Read the record ↗