Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
8 records match for Zimmer Biomet
20221 registryClear
Narrow it down
What happened
Country
Year
Not graded by the source2022-07-28FDA MAUDE0009617840-2022-00029ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THE SURGEON QUESTIONED THE ALIGNMENT ON POST OP X-RAY GIVEN THE PLANNED AND VALIDATED CUTS MEASURED DO NOT CORRELATE. PLANNED FOR NEUTRAL TO SLIGHT VALGUS KNEE OVERALL, STARTED AT 18 DEG VALGUS. VALIDATED CUTS SUGGEST WE SHOULD HAVE ENDED UP AT NEUTRAL OR CLOSE TO HOWEVER ON POST OP X-RAYS HAVE ENDED AT 10 DEG VARUS. THE PATIENT HAS ALSO REPORTED SIGNS OF PAIN AND INSTABILITY. THE PATIENT IS BEING CONSIDERED FOR A REVISION. NO ADDITIONAL INFORMATION.
cause not established0009617840-2022-00029Zimmer BiometRead the record ↗Not graded by the source2022-04-12FDA MAUDE0009617840-2022-00020ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A TKA ROBOTIC ASSISTED SURGERY THE POSTERIOR RESECTION WAS 4.5MM MORE THAN PLANNED ON BOTH SIDES, RESULTING IN AN UNEQUAL BALANCE BETWEEN EXTENSION AND FLEXION AND THE USE OF A THICKER POLY. NO KNOWN IMPACT OR CONSEQUENCE TO THE PATIENT AT THIS TIME. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
cause not established0009617840-2022-00020Zimmer BiometRead the record ↗Not graded by the source2022-03-11FDA MAUDE0009617840-2022-00017ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: NO ADDITIONAL INFORMATION ON THE REPORTED EVENT.
cause not established0009617840-2022-00017Zimmer BiometRead the record ↗Not graded by the source2022-02-23FDA MAUDE0009617840-2022-00011ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A ROBOTIC ASSISTED TKA THE TIBIA WAS OVER RESECTED BY 3 MM. DUE TO THIS DISCREPANCY, A 16MM POLY INSERT WAS USED INSTEAD OF THE PLANNED 13MM INSERT. NO ADDITIONAL PATIENT IMPACT HAS BEEN REPORTED OTHER THAN THE DEVIATION FROM PLANNED IMPLANT SIZE. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED AT THIS TIME.
cause not established0009617840-2022-00011Zimmer BiometRead the record ↗Not graded by the source2022-02-10FDA MAUDE0009617840-2022-00013ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A TKA PROCEDURE USING ROSA KNEE INSTRUMENTATION, THE PATIENT'S PROXIMAL TIBIA WAS OVER-RESECTED AND THE 4-IN-1 POSTERIOR FEMUR WAS UNDER RESECTED. THIS LEAD TO AN ANTERIOR FEMUR NOTCH, ALTHOUGH IT WAS WARNED AS POTENTIALLY AN ISSUE. SURGEON DECIDED TO PROCEED. ALL BONE CHIPS WERE CALIPERED. THERE WAS NO ADDITIONAL PATIENT IMPACT REPORTED. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
cause not established0009617840-2022-00013Zimmer BiometRead the record ↗Not graded by the source2022-01-12FDA MAUDE0009617840-2022-00009ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT FOLLOWING A TKA DONE BY ROSA KNEE SURGICAL INSTRUMENTATION, FEMORAL NOTCHING WAS NOTICED IN THE POST OPERATIVE X-RAYS. NO KNOWN IMPACT OR CONSEQUENCE TO THE PATIENT HAS BEEN REPORTED AT THIS TIME. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
cause not established0009617840-2022-00009Zimmer BiometRead the record ↗Not graded by the source2022-01-11FDA MAUDE0009617840-2022-00008ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A TKA SURGERY WITH ROSA INSTRUMENTATION, THE DISTAL FEMUR CUT WAS VALIDATED 3MM OVER THE PLANNED RESECTION. THE CUT WAS VALIDATED USING ROSA AND STANDARD CALIPERS. DUE TO THIS OVER-RESECTION OF THE DISTAL FEMUR, THE SURGEON DOWNSIZED BY 2 SIZES TO BALANCE THE SPACE. NO CONSEQUENCES OR IMPACT TO THE PATIENT. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
cause not established0009617840-2022-00008Zimmer BiometRead the record ↗Not graded by the source2022-01-06FDA MAUDE0009617840-2022-00007ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE ROSA PLATFORM DURING A TKA SURGERY, THERE WAS AN OVER RESECTION OF TIBIA BY 3MM. A THICKER THAN EXPECTED POLY IMPLANT HAD TO BE USED. NO ADDITIONAL CONSEQUENCES OR IMPACT TO THE PATIENT. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
cause not established0009617840-2022-00007Zimmer BiometRead the record ↗