Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
2 records match
20111 registryClear
Narrow it down
What happened
Country
Year
Not graded by the source2011-04-15FDA MAUDEAccuray2950679-2011-00002CyberKnife
CyberKnife — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: A PT TREATED FOR A MID-PARENCHYMAL LEFT LOWER LOBE MASS EXPERIENCED A COLLAPSE OF THE LEFT LOWER LOBE EIGHT MONTHS AFTER TREATMENT. THIS EVENT IS CONSIDERED A KNOWN RISK OF TREATING SUCH A TUMOR IN THIS LOCATION AND IS NOT ATTRIBUTED TO MALFUNCTION OF THE CYBERKNIFE SYSTEM. THE PT HAS DEMONSTRATED FAVORABLE RESPONSE TO TREATMENT WITH MARKED REGRESSION IN TUMOR SIZE AND IMPROVED CONTROL OF DISEASE.
cause not established2950679-2011-00002AccurayRead the record ↗Not graded by the source2011-01-01FDA MAUDEIntuitive Surgical, Inc.2955842-2022-12290da Vinci Surgical System
da Vinci Surgical System — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ON 26-NOV-2020, INTUITIVE SURGICAL, INC. (ISI) BECAME AWARE OF THE GENERAL THORACIC AND CARDIOVASCULAR SURGERY ARTICLE TITLED, ¿IS LEFT-SIDE DAVINCI PROCEDURE CHALLENGING? INITIAL EXPERIENCES OF A SINGLE INSTITUTE.¿ WITHIN THE ARTICLE, THE FOLLOWING IS NOTED: CASE #1 INVOLVED A 48-YEAR OLD FEMALE PATIENT WITH STAGE 1B CANCER WHO UNDERWENT A DA VINCI-ASSISTED LEFT UPPER LOBECTOMY PROCEDURE ON AN UNSPECIFIED DATE. THE CAUSE OF THE CONVERSION PER TABLE 3 IN THE ARTICLE WAS AN ¿INJURY OF PA¿ (PULMONARY ARTERY).¿IN CASE 1, THE CAUSE OF CONVERSION WAS UNCONTROLLABLE BLEEDING FROM AN INJURY TO THE LINGUAL SEGMENTAL PULMONARY ARTERY DURING STAPLING OF THE INCOMPLETE INTERLOBAR FISSURE.¿ FURTHERMORE, IT WAS NOTED IN REFERENCE TO CASE #1 (AND CASE #2) "IN BOTH CASES, CONVENTIONAL ENDOSCOPIC STAPLING DEVICES WERE EMPLOYED." ADDITIONALLY, THE ARTICLE STATES THE FOLLOWING: "WE EXPERIENCED TWO CONVERSIONS IN STAPLING THE FISSURE OF THE LEFT UPPER LOBE. BOTH CONVERSIONS WERE CAUSED BY FAILURE TO CONFIRM THAT THE TIP OF THE STAPLER WAS FREE FROM THE ADJACENT STRUCTURES. THIS IS PARTLY ATTRIBUTABLE TO THE SPECIFIC CHARACTERISTICS OF THE 30 DEGREE ANGLED SCOPE: IT IS DIFFICULT TO OBSERVE LATERALLY U
cause not established2955842-2022-12290Intuitive Surgical, Inc.Read the record ↗