Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
1,058 records match
2007–20261 registryClear
Narrow it down
What happened
Country
Year
Not graded by the source2024-02-02FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00555ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IN BETWEEN CASES SYSTEM FLAGGED ANOTHER "BUMP ERROR", THIS HAS HAPPENED 2 DAYS AFTER THE SITE HAD ANOTHER BUMP ERROR. THIS WAS RESOLVED VIA ACCURACY TEST PASS. SITE HAVE BEEN VIGILANT AND ASSURED ME THAT NO-ONE HAD IMPACTED THE CAMERA AND THE WARNING RANDOMLY APPEARED WHEN PREPPING FOR THE SECOND CASE.
cause not established3004142400-2024-00555Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-29FDA MAUDEAuris HealthMonarch Platform3014447948-2024-00002Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DURING THE CLINICAL STUDY TRIAL CASE UNEXPECTED VIDEO QUALITY WAS OBSERVED ON URETEROSCOPE. THE UNEXPECTED VIDEO QUALITY CONSISTED OF BLURRINESS ON THE SYSTEM DISPLAY. THE BLURRY VISION WAS ONLY OBSERVED DURING MINI-PERCUTANEOUS NEPHROLITHOTOMY (PCNL) PROCEDURE OF THE PRODUCT WORKFLOW, NAMELY DURING URETEROSCOPE DRIVING WITH THE LASER DRIVER COMPONENT CONNECTED. UPON REPLACEMENT OF THE URETEROSCOPE, NO FURTHER VIDEO ISSUES WERE OBSERVED AND THE USER COMPLETED THE CASE. UNDER PRELIMINARY INVESTIGATION THE URETEROSCOPE WAS EXAMINED UNDER MAGNIFICATION, AT WHICH TIME IT WAS DISCOVERED THAT THE TOP LAYER OF THE CAMERA LENS WAS MISSING. THERE WERE NO REPORTED ADVERSE EFFECTS TO THE PATIENT BECAUSE OF THE SYSTEM ISSUES.
cause not established3014447948-2024-00002Auris HealthMonarch PlatformRead the record ↗Not graded by the source2024-01-26FDA MAUDEDePuy SynthesVELYS™ Robotic-Assisted Solution1818910-2024-04395VELYS
VELYS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A TOTAL KNEE ARTHROPLASTY SURGICAL PROCEDURE, IT WAS OBSERVED THAT WHILE USING THE ROBOTIC-ASSISTED SOLUTION SATELLITE STATION DEVICE IT WAS NOTICED THAT THE ANTERIOR CUT WAS OFF. IT WAS ALSO REPORTED THAT THE ROBOTIC ASSISTED BASE STATION DEVICE WAS TAKING A LONG TIME TO BOOT UP AND THE POWER CORD WOULD NOT STAY SECURELY ATTACHED TO THE BASE STATION. IT WAS REPORTED THAT THE SYSTEM WAS WORKING HOWEVER THE POWER CORD IS CAUSING FRUSTRATION WITH THE SYSTEM SHUTTING DOWN. THERE WERE NO DELAYS IN THE PROCEDURE. THERE WAS PATIENT INVOLVEMENT. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.
cause not established1818910-2024-04395DePuy SynthesVELYS™ Robotic-Assisted SolutionRead the record ↗Not graded by the source2024-01-24FDA MAUDEGlobus MedicalExcelsiusGPSMW5151748ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE PATIENT WAS SCHEDULED FOR A LUMBAR FUSION WITH SPINAL INSTRUMENTATION USING COMPUTER NAVIGATION AND ROBOTIC ASSISTANCE USING THE GLOBUS MEDICAL EXCELSIUS 3D IMAGING SYSTEM. I HAD BEEN NOTIFIED BY THE GLOBUS REPRESENTATIVE ON THE MORNING OF SURGERY THAT THERE WAS A POTENTIAL PROBLEM WITH THE BATTERY SUPPLY OF THE GLOBUS IMAGING SYSTEM BUT THAT IT HAD BEEN ADDRESSED BY THE ENGINEERS AND THERE SHOULD BE NO PROBLEM. I WAS TOLD THAT EVEN IF THERE WAS A BATTERY ISSUE THE SYSTEM COULD RUN FROM ELECTRICAL POWER FROM THE WALL. ONCE THE PATIENT WAS ASLEEP AND THE EXPOSURE TO THE SPINE WAS COMPLETE, THE GLOBUS IMAGING SYSTEM WAS BROUGHT IN FOR OBTAINING THE IMAGES. IT IMMEDIATELY SHUT DOWN AND COULD NOT BE RESTARTED. AS A RESULT I WAS UNABLE TO PROCEED WITH THE COMPUTER NAVIGATION OR ROBOTIC ASSISTANCE THAT I HAD EXPLAINED TO THE PATIENT. MY OPTIONS WERE TO EITHER CANCEL THE SURGERY AND CLOSE THE WOUND TO RETURN ANOTHER DAY ONCE THE SYSTEM WAS WORKING OR PROCEED WITHOUT THE NAVIGATION AND ROBOTIC ASSISTANCE. I CHOOSE TO PROCEED WITH THE SURGERY USING THE TRADITIONAL APPROACH WITHOUT NAVIGATION OR ROBOTICS. FORTUNATELY THE SURGERY WENT WELL WITHOUT COMPLICATIONS. I WAS ABLE TO CONTINUE WIT
cause not establishedMW5151748Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-24FDA MAUDEGlobus MedicalExcelsiusGPSMW5151747ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE PATIENT WAS SCHEDULED FOR A LUMBAR FUSION WITH SPINAL INSTRUMENTATION USING COMPUTER NAVIGATION AND ROBOTIC ASSISTANCE USING THE GLOBUS MEDICAL EXCELSIUS 3D IMAGING SYSTEM. I HAD BEEN NOTIFIED BY THE GLOBUS REPRESENTATIVE ON THE MORNING OF SURGERY THAT THERE WAS A POTENTIAL PROBLEM WITH THE BATTERY SUPPLY OF THE GLOBUS IMAGING SYSTEM BUT THAT IT HAD BEEN ADDRESSED BY THE ENGINEERS AND THERE SHOULD BE NO PROBLEM. I WAS TOLD THAT EVEN IF THERE WAS A BATTERY ISSUE THE SYSTEM COULD RUN FROM ELECTRICAL POWER FROM THE WALL. ONCE THE PATIENT WAS ASLEEP AND THE EXPOSURE TO THE SPINE WAS COMPLETE, THE GLOBUS IMAGING SYSTEM WAS BROUGHT IN FOR OBTAINING THE IMAGES. IT IMMEDIATELY SHUT DOWN AND COULD NOT BE RESTARTED. AS A RESULT I WAS UNABLE TO PROCEED WITH THE COMPUTER NAVIGATION OR ROBOTIC ASSISTANCE THAT I HAD EXPLAINED TO THE PATIENT. MY OPTIONS WERE TO EITHER CANCEL THE SURGERY AND CLOSE THE WOUND TO RETURN ANOTHER DAY ONCE THE SYSTEM WAS WORKING OR PROCEED WITHOUT THE NAVIGATION AND ROBOTIC ASSISTANCE. I CHOOSE TO PROCEED WITH THE SURGERY USING THE TRADITIONAL APPROACH WITHOUT NAVIGATION OR ROBOTICS. FORTUNATELY THE SURGERY WENT WELL WITHOUT COMPLICATIONS. I WAS ABLE TO CONTINUE WIT
cause not establishedMW5151747Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-24FDA MAUDEGlobus MedicalExcelsiusGPSMW5151749ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE PATIENT WAS SCHEDULED FOR A LUMBAR FUSION WITH SPINAL INSTRUMENTATION USING COMPUTER NAVIGATION AND ROBOTIC ASSISTANCE USING THE GLOBUS MEDICAL EXCELSIUS 3D IMAGING SYSTEM. I HAD BEEN NOTIFIED BY THE GLOBUS REPRESENTATIVE ON THE MORNING OF SURGERY THAT THERE WAS A POTENTIAL PROBLEM WITH THE BATTERY SUPPLY OF THE GLOBUS IMAGING SYSTEM BUT THAT IT HAD BEEN ADDRESSED BY THE ENGINEERS AND THERE SHOULD BE NO PROBLEM. I WAS TOLD THAT EVEN IF THERE WAS A BATTERY ISSUE THE SYSTEM COULD RUN FROM ELECTRICAL POWER FROM THE WALL. ONCE THE PATIENT WAS ASLEEP AND THE EXPOSURE TO THE SPINE WAS COMPLETE, THE GLOBUS IMAGING SYSTEM WAS BROUGHT IN FOR OBTAINING THE IMAGES. IT IMMEDIATELY SHUT DOWN AND COULD NOT BE RESTARTED. AS A RESULT I WAS UNABLE TO PROCEED WITH THE COMPUTER NAVIGATION OR ROBOTIC ASSISTANCE THAT I HAD EXPLAINED TO THE PATIENT. MY OPTIONS WERE TO EITHER CANCEL THE SURGERY AND CLOSE THE WOUND TO RETURN ANOTHER DAY ONCE THE SYSTEM WAS WORKING OR PROCEED WITHOUT THE NAVIGATION AND ROBOTIC ASSISTANCE. I CHOOSE TO PROCEED WITH THE SURGERY USING THE TRADITIONAL APPROACH WITHOUT NAVIGATION OR ROBOTICS. FORTUNATELY THE SURGERY WENT WELL WITHOUT COMPLICATIONS. I WAS ABLE TO CONTINUE WIT
cause not establishedMW5151749Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-23FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00549ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THERE IS A RED LIGHT ON THE ROBOT, AND THE SYSTEM CAMERA REPORTED BING BUMPED.
cause not established3004142400-2024-00549Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-12FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00131ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2024-00131Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-12FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00020ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT A REVISION SURGERY WAS NEEDED TO REMOVE AND REPLACE MISPLACED SCREWS THAT WERE PLACED USING THE EXCELSIUS GPS SYSTEM DUE TO ADVERSE PATIENT EFFECTS.
cause not established3004142400-2024-00020Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-05FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00543ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DR. (B)(6) WAS DOING A T3-T12 PEDIATRIC SCOLIOSIS PATIENT. SIGNIFICANT CORONAL AND SAGITTAL DEFORMITY AT MULTIPLE LEVELS. WE WERE USING A 12INCH C-ARM. MERGE FAILED AFTER MULTIPLE ATTEMPTS OF HAVING THE X-RAY TECH WAG THE C-ARM IN LATERAL, RAINBOW IN A/P, AND TRY OBLIQUE IN LATERAL AT HIGH LEVELS. TRIED MULTIPLE LATERALS AND A/P WITH NO AVAIL. SURGEON WAS VERY PATIENT AND GAVE US THE TIME BUT EVENTUALLY BAILED ON THE ROBOT. HE PROCEEDED WITH DOING THE CASE FREE HAND.
cause not established3004142400-2024-00543Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-04FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00035Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PATIENT EXPERIENCED A PNEUMOTHORAX IN THE RIGHT LUNG. A CHEST TUBE WAS PLACED AND PATIENT WAS HOSPITALIZED. THE FOLLOWING DAY THE CHEST TUBE WAS REMOVED AND THE PATIENT WAS RELEASED. THE PHYSICIAN STATED THAT THE SCOPE APPEARED TO BE KINKED AND THE PHYSICIAN ELECTED TO ABORT THE CASE.
cause not established3014447948-2023-00035Auris HealthMonarch PlatformRead the record ↗Not graded by the source2024-01-03FDA MAUDEAuris HealthMonarch Platform3014447948-2024-00007Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT REPORTED THAT THE NAVIGATION WAS NOT MATCHING UP WITH THE CIOS SPIN AND WAS ~30MM OFF FROM THE TARGET BUT THE CASE WAS COMPLETED SUCCESSFULLY. A PNEUMOTHORAX WAS DISCOVERED POST-OP AND THE PATIENT WAS NOT ADMITTED BUT A CHEST TUBE WAS PLACED. CHEST TUBE WAS REMOVED SAME DAY AND THE PATIENT WENT HOME SAME DAY. THERE WERE NO FAULTS OR ISSUES REPORTED WITH THE MONARCH SYSTEM AND THE PHYSICIAN IS NOT ATTRIBUTING THE EVENT TO THE MONARCH.
cause not established3014447948-2024-00007Auris HealthMonarch PlatformRead the record ↗Not graded by the source2024-01-03FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00277ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2024-00277Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-03FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00544ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE MERGE OF L4-5 LEVELS FOR SINGLE POSITION LATERAL SURGERY SHOWED A SHIFT. WE TOOK NEW SHOTS OF EACH INDIVIDUAL LEVEL AND ADDED L3 AND S1 TO HELP WITH THE MERGE. THE SURGEON WAS UNHAPPY WITH THE MERGE AS THERE WAS SLIGHT MOVEMENT VISIBLE ON THE L4 AND L5 A/P AND LATERAL VIEWS. THE SINGLE POSITION LATERAL CASE WAS ABORTED AND CONVERTED TO AN OPEN PRONE TLIF. PLEASE NOTE THE BED WAS ADJUSTED TO HELP ACCOMMODATE THE ILIAC CREST PRIOR TO ROBOTIC X RAYS BEING TAKEN.
cause not established3004142400-2024-00544Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2024-01-01FDA MAUDEDePuy SynthesVELYS™ Robotic-Assisted Solution1818910-2024-04010VELYS
VELYS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHEN VERIFYING THE CUTS ON THE FEMUR, IT APPEARED THAT THE LATERAL POSTERIOR CUT HAD BEEN OVER RESECTED BY 1MM WHEN USING VELYS. WHEN SURGEON PUT TRIALS ON, HE NOTICED CONSIDERABLE 1-2MM GAPS BETWEEN BONE AND TRIAL FEMUR FOR THE: POSTERIOR, ANTERIOR, ANTERIOR CHAMFER AND DISTAL. LEFT TKR USING VELYS ATTUNE PS FB CONSTRUCT.
cause not established1818910-2024-04010DePuy SynthesVELYS™ Robotic-Assisted SolutionRead the record ↗Not graded by the source2023-12-26FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00013ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT A REVISION SURGERY WAS NEEDED TO REMOVE AND REPLACE MISPLACED SCREWS THAT WERE PLACED USING THE EXCELSIUS GPS SYSTEM DUE TO ADVERSE PATIENT EFFECTS (FOOTDROP).
cause not established3004142400-2024-00013Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-22FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00542ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: WHEN ASSEMBLING THE A/O DRIVER AND ELECTRODE CLAMP GUIDE TUBE, IT WAS NOTED THAT THE SURGEON WAS ABLE TO SPIN THE E.C GUIDE TUBE. HOWEVER, THE E.C. GT APPEARED TO BE ASSEMBLED AS EXPECTED.
cause not established3004142400-2024-00542Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-20FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00276ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE EXCELSIUS GPS SYSTEM, THE CASE WAS ABORTED DUE TO THE ROBOT BECOMING UNRESPONSIVE, AND SCREWS WERE THEN PLACED WITHOUT ROBOT.
cause not established3004142400-2024-00276Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-20FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00541ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ROBOT DOES NOT RECOGNIZE WHEN THE POWER CORD IS PLUGGED IN. WORKED FINE FOR A CASE LAST NIGHT, BUT WHEN TURNING ON TODAY TO DO A CASE IT WOULD NOT CHARGE THE BATTERY AND WAS RUNNING SOLELY OFF THE BATTERY WHEN TURNED ON. THINK A FUSE IS BLOWN IN THE ROBOT.
cause not established3004142400-2024-00541Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-18FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00539ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE ROBOT IS DISPLAYING A BLACK SCREEN WITH WHITE LETTERS ON BOOT UP SAYING "REBOOT AND SELECT PROPER BOOT DEVICE OR INSERT BOOT MEDIA IN SELECTED BOOT DEVICE AND PRESS A KEY".
cause not established3004142400-2024-00539Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-18FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00540ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: (B)(6), LLIF L2-5 (FLUOROSCOPY WORKFLOW), PLDF L2-ILIUM (PREOP/INTRAOP WORKFLOW). FOR LLIF PORTION OF PROCEDURE FLUOROSCOPY WORKFLOW USED. L3/4 AND L4/5 REGISTERED AND L4/5 INSTRUMENTED FIRST. SURGEON STATED CAGE ENDED UP MORE POSTERIOR THAN PLANNED. L2/3 AND L3/4 REGISTERED AGAIN AND AGAIN, SURGEON STATED CAGE WAS PLACED MORE POSTERIORLY THAN NAVIGATION STATED. SURGEON DECLINED TO REGISTER L2/3 AGAIN AND CAGE PLACED. IN THE END, SURGEON STATED ALL CAGES WERE PLACED MORE POSTERIORLY THAN HE EXPECTED BASED ON THE NAVIGATION SHOWING HIM PLACING CAGES ANTERIOR TO FINAL POSITION.
cause not established3004142400-2024-00540Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-15FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00262ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE EXCELSIUS GPS SYSTEM, THE CASE WAS ABORTED DUE TO ROBOTIC ERROR.
cause not established3004142400-2024-00262Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-15FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00536ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ROBOT BROUGHT INTO ROOM AND TURNED ON WITHOUT ANY ISSUES. SCREEN WENT TO A BLUE SCREEN WITH MESSAGE "A START UP ERROR HAS OCCURRED". TRIED MULTIPLE RESTARTS AND ERROR STILL OCCURRED. CASE HAD TO BE ABORTED.
cause not established3004142400-2024-00536Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-14FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00538ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DURING A DBS PROCEDURE AN IDENTICAL BILATERAL DEVIATION WAS NOTICED EVEN WITH 3 REGISTRATIONS. THE PATIENT HAD A BONE FIDUCIAL PLACED AND AN INITIAL NON-STERILE REGISTRATION WITH O ARM SET TO THE STEREOTAXY SETTINGS WAS PERFORMED AND ACCURACY CHECKS WERE PERFORMED. IT WAS NOTICED THAT THE INITIAL REGISTRATION FIT WAS NOT CENTERED ON ALL SPHERES AND REQUIRED A FAIR AMOUNT OF MANIPULATION TO GET INTO A GREEN FIT. ACCURACY CHECKS WERE PERFORMED, INCLUDING WITH THE BONE FIDUCIAL AND SHOWED AN ACCEPTABLE REGISTRATION. THE PATIENT WAS DRAPED AND ACCURACY CHECKS WERE PERFORMED AGAIN SHOWING NO CHANGE IN ACCURACY. THE BURR HOLES WERE CREATED AT WHICH POINT THE PATIENT COUGHED. I ADVISED TO PERFORM ADDITIONAL ACCURACY CHECKS TO THE BONE FIDUCIAL SHOWING A 2-3 MM SHIFT POSTERIOR. A STERILE ICT AND ARM WERE ATTACHED AND ANOTHER O ARM SCAN WITH THE SAME SETTING WAS PERFORMED. THERE WAS A SIMILAR REGISTRATION FIT WITH THIS REGISTRATION AS WELL. ACCURACY CHECKS WERE PERFORMED AND THE LEAD WAS PERFORMED ON THE RIGHT SIDE. AN EVALUATION SCAN WAS PERFORMED SHOWING A 3 MM POSTERIOR MEDIAL DEVIATION. THE LEAD WAS LEFT DUE TO RESPONSIVE TESTING. THE PATIENT COUGHED AGAIN AND ANOTHER REGISTRATION WAS P
cause not established3004142400-2024-00538Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-08FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00005ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT A REVISION SURGERY WAS NEEDED TO REMOVE AND REPLACE MISPLACED SCREWS THAT WERE PLACED USING THE EXCELSIUS GPS SYSTEM.
cause not established3004142400-2024-00005Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-12-04FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00032Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED DURING A MONARCH BRONCHOSCOPY PROCEDURE AN E-STOP ERROR OCCURRED. THE PHYSICIAN WAS UNABLE TO CLEAR THE E-STOP ERROR AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED ADVERSE EFFECTS TO THE PATIENT BECAUSE OF THE SYSTEM ISSUES.
cause not established3014447948-2023-00032Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-29FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00033Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A SUCCESSFUL DIAGNOSTIC PROCEDURE USING THE MONARCH BRONCHOSCOPY SYSTEM, THE PATIENT DEVELOPED A PNEUMOTHORAX AND LATER PASSED AWAY. THERE WAS NO REPORTED DEVICE MALFUNCTION ASSOCIATED WITH THE ADVERSE EVENT. PER THE ACCOUNT MANAGER, HOSPITAL ENDO MANAGEMENT DOES NOT ATTRIBUTE THE PNEUMOTHORAX OR THE SUBSEQUENT DEATH TO ANY DEFICIENCY OF THE MONARCH SYSTEM.
cause not established3014447948-2023-00033Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-29FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00534ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS INFORMED THAT ONE CASE OF L1-L4 MIS FIXATION WITH INTRAOP (O-ARM)WORKFLOW WAS BEING DONE AND THE PLANNING WAS DONE AFTER REGISTRATION. SURGEON HAD ALREADY PLACED L1 LEFT, L2 LEFT & L3 LEFT SCREWS. AFTER DRILLING IN L4 LEFT PEDICLE, SURGEON HAS CHECKED WITH BALL TIP PROBE AND OBSERVED THAT SOMETHING WAS WRONG, AND HE STOPPED THE PROCEDURE. AFTER CHECKING WITH C-ARM SHOT IT WAS FOUND THAT ALL THREE PLACED SCREWS ARE NOT AS PER THE PLAN AND ALL THE SCREWS WERE SHIFTED MEDIALLY AND CAUDALLY. AFTER THAT SURGEON HAS STOPPED USING ROBOT AND REPOSITIONED ALL THE SCREWS MANUALLY.
cause not established3004142400-2024-00534Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-29FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00251ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE EXCELSIUS GPS SYSTEM, THE CASE WAS ABORTED AND SCREWS WERE THEN PLACED BY HAND. THIS EVENT OCCURRED IN GERMANY.
cause not established3004142400-2024-00251Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-23FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00533ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THIS WAS AN INTRAOP ADOLESCENT SCOLI CASE T4-L5 WITH A SIEMENS CIOS SPIN. WE DIVIDED THE CASE INTO THREE SEGMENTS (L2-L5, T9-T11 AND T4-T6) AND REIMAGED THE PATIENT. APPARENTLY, THE TECHNICIAN CANNOT ISOLATE THE SINGLE SCAN, SO ALL SCANS WERE TRANSFERRED WITH THE LAST ONE. DURING THE NAVIGATION ON THE LAST SEGMENT, THE IMAGE OF THE SCAN WAS KIND OF TORN AND THE SAGITTAL AND AXIAL PLANE LOOKED ALIKE. RESET SOFTWARE, HARD DID NOT HELP, DID A HARD SHUTDOWN AND RESTART. THE ISSUE WITH THE SCAN WAS STILL THERE AND COULD NOT BE SOLVED. THE LAST THREE TRAJECTORIES WERE DRILLED WITH THE ROBOT, BUT SCREWS WERE INSERTED FREEHANDED.
cause not established3004142400-2024-00533Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-20FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00532ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: GPS UNIT IS HAVING HARD DRIVE ISSUES. IT WILL ONLY DISPLAY A BLACK SCREEN WHEN BOOTING UP STATING "REBOOT AND SELECT PROPER BOOT DEVICE OR INSERT BOOT MEDIA IN SELECTED BOOT DEVICE AND PRESS A KEY."
cause not established3004142400-2024-00532Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-17FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00223ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2024-00223Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-15FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00528ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE CASE WAS AN L4-S1 ALIF 360 USING HEDRON IA AND CREO ONE HARDWARE. THERE WAS NO PRIOR HARDWARE IN THE PATIENT. THE EGPS WORKFLOW WAS INTRA-OP CT. THE EGPS IS RUNNING SOFTWARE VERSION 1_1R3. THE PATIENT WAS POSITIONED PRONE FOR THE POSTERIOR PORTION AND THE CAMERA WAS POSITIONED AT THE FOOT OF THE BED. AN O-ARM WAS USED FOR IMAGING AND REGISTRATION. DR. (B)(6) PLACED THE DRB AT RIGHT PSIS WITH THE LOW-PROFILE QUATTRO SPIKE AND SURVEILLANCE MARKER AT LEFT PSIS. SURVEILLANCE WAS REGISTERED PRIOR TO THE ICT BEING POSITIONED ON THE QUATTRO SPIKE. THE ICT WAS POSITIONED, THE BED WAS RAISED, AND THE SURGICAL SNAPSHOT WAS TAKEN. THE O-ARM SPIN WAS ACQUIRED AND TRANSFERRED SUCCESSFULLY TO EGPS VIA ETHERNET. ALL 7 FIDUCIALS WERE CAPTURED SUCCESSFULLY, AND THE REGISTRATION FIT WAS DOWN ON GREEN. DR. (B)(6) PERFORMED LANDMARK CHECKS ON THE ICT FIDUCIALS AS WELL AS DOWN THE LOW-PROFILE QUATTRO SPIKE. NAVIGATION APPEARED TO EVERYONE IN THE ROOM TO BE ACCEPTABLE AND OF HIGH QUALITY. FOLLOWING PERCUTANEOUS PLACEMENT OF ALL SCREWS THROUGH BILATERAL WILTSY INCISIONS, A POST-OP REGISTRATION O-ARM SPIN WAS ACQUIRED. DR. (B)(6) DECIDED TO DO THIS PRIOR TO LOCKING THE CONSTRUCT DOWN AS HE QUESTIONED
cause not established3004142400-2024-00528Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-14FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00531ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE SURGEONS COMPLAINT WAS THE FACT THAT WHILE ATTEMPTING TO MERGE THE L2 VERTEBRAL BODY, HE WAS UNABLE TO GET A BETTER MERGE BECAUSE OF THE LORDOTIC SHIFTING.
cause not established3004142400-2024-00531Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-14FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00527ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: WE WERE INSTRUMENTING PEDICLE SCREWS AT T12 & L2 , SKIPPING THE FRACTURE LEVEL. THE E3D SPIN WENT FINE, AND INITIAL NAV INTEGRITY CHECKS SEEMED FINE AS WELL. WE PLACED ALL 4 SCREWS AT T12 / L2. WE BATTLED A LITTLE BIT OF SAVING BUT NOTHING SIGNIFICANT. WE TOOK AP SHOT AFTER SCREWS WERE PLACED, AND ALL FOUR SCREWS WERE COMPLETELY OUT OF THE PEDICLE. THE LEFT SIDE WAS LATERAL, AND RIGHT SIDE WAS MEDIAL.
cause not established3004142400-2024-00527Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-13FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00526ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ALL OUR SCREWS WERE ON, WE USED PRE OP CT WORKFLOW WITH G-ARM. THEN WE TOOK AN X-RAY OF OUR LATERAL TRIAL, AND THE NAVIGATION WAS ON. WHEN PLACING THE IMPLANT, WE WERE 4/5MM OFF POSTERIOR. WE HAD TO GO BACK IN, OPEN THE PATIENT, RETRIEVE THE CAGE AND RE DO EVERYTHING, NAVIGATION APPEARED TO BE ON UP UNTIL THE CAGE.
cause not established3004142400-2024-00526Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-11FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00529ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: APOLOGIES, ORIGINAL REPORT DID NOT PROCESS. LOGS HAVE BEEN UPLOADED TO INR PORTAL. THERE WAS A SUSPECTED ISSUE WITH THE PREOP REGISTRATION/MERGE. T12 FRACTURE, SCREWS PLACED AT T10-11, L1-2. NAMELY, T11-L WAS PLACED LATERAL TO THE ORIGINAL PLACE. ADDITIONALLY, T10 SCREWS PLACED PROUD. AFTER DISCUSSION, SUSPECTED MISSTEP MAY HAVE BEEN PROPER PLACEMENT OF FLUORO FIXTURE BUT NO YET CAUSE DETERMINED. SCREWS WERE REPOSITIONED VIA TRADITIONAL MIS JAMSHID TECHNIQUE.
cause not established3004142400-2024-00529Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-10FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00030Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN WAS ADJUSTING THE SCOPE TOWARDS TARGET OF NODULE AND THE PATIENTS HEART RATE (HR) BEGAN TO DECLINE AND THE PHYSICIAN ABORTED THE CASE. THE PATIENT THEN WENT INTO ASYSTOLE AND REQUIRED EMERGENT CONVERSION AND CHEST COMPRESSIONS. ONCE THE PATIENT REGAINED A PULSE THE WERE TRANSPORTED THE INTENSIVE CARE UNIT (ICU) WHERE THE PATIENT CODED AGAIN AND WAS BEING SENT TO THE CARDIAC CATH LAB. THE PHYSICIAN STATED THAT THE ADVERSE EVENTS ARE NOT ATTRIBUTED TO THE MONARCH SYSTEM.
cause not established3014447948-2023-00030Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-10FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00031Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN WAS ADJUSTING THE SCOPE TOWARDS TARGET OF NODULE AND THE PATIENTS HEART RATE (HR) BEGAN TO DECLINE AND THE PHYSICIAN ABORTED THE CASE. THE PATIENT THEN WENT INTO ASYSTOLE AND REQUIRED EMERGENT CONVERSION AND CHEST COMPRESSIONS. ONCE THE PATIENT REGAINED A PULSE THE WERE TRANSPORTED THE INTENSIVE CARE UNIT (ICU) WHERE THE PATIENT CODED AGAIN AND WAS BEING SENT TO THE CARDIAC CATH LAB. THE PHYSICIAN STATED THAT THE ADVERSE EVENTS ARE NOT ATTRIBUTED TO THE MONARCH SYSTEM.
cause not established3014447948-2023-00031Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-09FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00530ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: THE PLANNED SURGERY ON THE DORSAL CERVICAL SPINE INCLUDED A SCREW FIXATION C1/C3/C4. WHEN CHECKING THE SCREW POSITION IN THE 3D SCAN AFTER SCREW PLACEMENT, THE SURGEONS WERE NOT SATISFIED WITH THE SCREW POSITION OF A C1 SCREW. A NEW 3D SCAN WAS PERFORMED AND A NEW C1 SCREW WAS PLANNED INTRAOPERATIVELY. WHEN APPROACHING THE TRAJECTORY, THE ROBOTIC ARM STOPPED FAR AWAY FROM THE FINAL POSITION AND ONLY SHOWED A YELLOW FRAME. THE END EFFECTOR WAS SO FAR AWAY THAT THE INSTRUMENTS DID NOT REACH THE BONE. RESETTING THE SOFTWARE AND MOVING THE ROBOT ARM MANUALLY DID NOT CHANGE ANYTHING. BECAUSE THE ROBOT ARM WAS TOO FAR AWAY, THE C1 SCREW HAD TO BE INSERTED MANUALLY (WITH NAVIGATION OF THE ROBOT), BUT NOT BY THE END EFFECTOR.
cause not established3004142400-2024-00530Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-09FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00034Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT REPEATED SYSTEM FAULTS OCCURRED DURING A MONARCH BRONCHOSCOPY. THE PHYSICIAN TRIED MULTIPLE BRONCHOSCOPES, BUT THE SYSTEM CONTINUED TO FAULT. THE PHYSICIAN ELECTED TO ABORT THE DIAGNOSTIC PROCEDURE. NO CLINICAL CONSEQUENCES TO THE PATIENT WERE REPORTED DUE TO THIS EVENT.
cause not established3014447948-2023-00034Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-08FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2023-00196ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT A SCREW USING THE EXCELSIUS GPS SYSTEM WAS MISPLACED INTRA-OPERATIVELY CAUSING A SCREW TO BREACH THE PATIENT'S SPINAL CANAL.
cause not established3004142400-2023-00196Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-07FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2023-00194ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT A REVISION SURGERY WAS NEEDED TO REMOVE AND REPLACE MISPLACED SCREWS THAT WERE PLACED USING THE EXCELSIUS GPS SYSTEM.
cause not established3004142400-2023-00194Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-03FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00521ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: CAMERA IS BROKEN FULL DESCRIPTION ENTIRE SYSTEM NEEDS TO BE RUN FOR BUGS CAMERA IS BROKEN STORAGE IS LOW AND COMPUTER IS SLOW NEED TO BE DONE ASAP.
cause not established3004142400-2024-00521Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-11-03FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00029Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT PHYSICIAN OBSERVED EXCESS AMOUNT OF BLOOD IN THE AIR WAY AFTER SUCCESSFULLY COMPLETING THE MONARCH BRONCHOSCOPY PROCEDURE. THE PHYSICIAN ELECTED TO USE THEIR MANUAL BRONCHOSCOPE AND COLD SALINE TO CLEAR THE AIRWAY; HOWEVER, COMPLICATIONS OCCURRED DURING THE POST-MONARCH BRONCHOSCOPY PROCEDURE. THE PATIENTS BLOOD HAD CLOTTED AND BLOCKED THE ENDOTRACHEAL TUBE (ET TUBE). THE PATIENT THEN FELL INTO CARDIAC ARREST DUE TO LACK OF VENTILATION FROM THE FROM THE BLOOD CLOT BEING PRESENT IN THE ENDOTRACHEAL TUBE (ET TUBE). THE PHYSICIAN FOLLOWED CARDIAC ARREST PROTOCOL AND WAS ABLE TO RECOVER THE PATIENT. THE PATIENT WAS ADMITTED INTO INTENSIVE CARE UNIT (ICU) ON THE SAME DAY. AFTER THE PATIENT WAS SENT TO RECOVERY IN THE INTENSIVE CARE UNIT (ICU), THE PATIENT WAS GIVEN A CHEST X-RAY WHERE DOCTOR DISCOVERED THE PATIENT HAD EXPERIENCED A PNEUMOTHORAX. A CHEST TUBE WAS PLACED AND REMOVED THE FOLLOWING DAY. THE PHYSICIAN STATED THE PNEUMOTHORAX WAS DUE TO LONG BAG VENTILATION TIME, EXCESS SUCTION, AND OVER ALL STRESS ON THE LUNG THAT OCCURRED DURING BLEEDING MANAGEMENT POST-MONARCH PROCEDURE. THE PATIENT HAS BEEN RELEASED FROM THE HOSPITAL.
cause not established3014447948-2023-00029Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-11-02FDA MAUDEAuris HealthMonarch Platform3014447948-2023-00028Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DIAGNOSTIC PROCEDURE USING THE MONARCH BRONCHOSCOPY SYSTEM, THE PHYSICIAN DECIDED TO ABORT THE DIAGNOSTIC PROCEDURE DUE TO NAVIGATIONAL DIFFICULTY AND POOR VISIBILITY. PATIENT MUCUS CONTRIBUTED SIGNIFICANTLY TO THE POOR VISIBILITY. THE PHYSICIAN DECIDED TO CONVERT THE DIAGNOSTIC PROCEDURE TO A MANUAL BRONCHOSCOPY PROCEDURE. IT WAS REPORTED THAT THE PATIENT DEVELOPED A PNEUMOTHORAX AND A CHEST TUBE WAS PLACED.
cause not established3014447948-2023-00028Auris HealthMonarch PlatformRead the record ↗Not graded by the source2023-10-30FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00519ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2024-00519Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-10-30FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00518ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: TRYING TO START A CASE AND THE ROBOT WENT TO REBOOT AND SELECT PROPER BOOT DEVICE. NEED AN FSE FOR TOMORROW'S CASE WITH A NEW SURGEON.
cause not established3004142400-2024-00518Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-10-29FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00524ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DURING ROBOTIC REGISTRATION THE FLUORO SHOTS AND PRE-OP CT SCAN DID NOT ALIGN PROPERLY. WITH CLEAR FLUORO PHOTOS IT LOOKED AS IF THE ROBOT WAS PULLING AN OBLIQUE CT SLICE. WE HELD RESPIRATION, CENTERED EACH VERTEBRAE, SOFTWARE RESET, SWITCHED TO CRANIAL AND BACK WITH NO SUCCESS. I USED LIFE SAVER, BUT AT THAT POINT DR. (B)(6) CHOSE NOT TO CONTINUE WITH THE ROBOT.
cause not established3004142400-2024-00524Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2023-10-27FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2024-00525ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS THE INTRA-OP SPINE CASE. UNFORTUNATELY, THE TEAM COULDN'T GET THE AUTOMATIC REGISTRATION. IT HAD BEEN DONE ANOTHER SCAN WITH THE SAME RESULT. AFTER THE REGISTRATION WAS DONE MANUALLY, THE SURGEON NOTICED SOME NAVIGATION SHIFTS. THE ROBOTIC CASE WAS ABORTED AND DONE TRADITIONALLY. NO ADVERSE EFFECTS FOR THE PATIENT.
cause not established3004142400-2024-00525Globus MedicalExcelsiusGPSRead the record ↗