Every incident, injury and recall on file, from the national registries that publish them. Search a maker, a model, a town or a reference number — or narrow by what happened. Each record is the registry's own text, reproduced without rewriting, with the reference that locates it at the source. Registries count different things, so a total is a count of FILINGS and never a measure of how dangerous something is. How the record was collected.
Or jump to a maker
645 records match
10 death reports20258 registriesClear
Narrow it down
What happened
Country
Year
Not graded by the source2025-05-20FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00020Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE, THE PHYSICIAN ENCOUNTERED NAVIGATION ISSUES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00020Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-05-20FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00019Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED SYSTEM FAULT MESSAGES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00019Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-05-12FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00143ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT IMPLANTS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2025-00143Globus MedicalExcelsiusGPSRead the record ↗Recall2025-05-07EU Safety GateSR/00867/25Poolrunner Battery Pro Performance
Poolrunner Battery Pro Performance — Fully automatic battery-operated pool robot for cleaning pools, powered by a rechargeable battery. Product sold online, in particular via steinbach-group.com. Hazard (Burns, Fire): A technical defect in the charging station or the battery could cause a fire and burns to the user. The product does not comply with the Low Voltage Directive. Action: Recall of the product from end users.
cause not establishedSR/00867/25Read the record ↗Not graded by the source2025-05-06FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00018Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED NAVIGATION ACCURACY ISSUES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT..
cause not established3014447948-2025-00018Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-05-06FDA MAUDEAuris HealthMonarch PlatformMW5170510Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DURING MULTIPLE PROCEDURES, THE MONARCH ROBOT NAVIGATION SYSTEM WAS UNSURE WHICH AREA OF THE LUNG IT WAS IN WITH DISTANCE MEASUREMENTS VARYING UP TO 30MM. BIOMED WAS ABLE TO RECREATE PRODUCT ISSUE IN DEMO ENVIRONMENT. PROBLEMS INTERMITTENTLY BEGAN AFTER SOFTWARE UPDATE 5 WEEKS AGO BUT BECAME MORE CONSISTENT LAST WEEK.
cause not establishedMW5170510Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-05-06FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00017Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED SYSTEM FAULT MESSAGES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00017Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-05-02FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00125ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE EXCELSIUS GPS SYSTEM, THE CASE WAS ABORTED DUE TO PATIENT INJURY.
cause not established3004142400-2025-00125Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2025-04-30FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00016Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED SYSTEM FAULT MESSAGES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00016Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-04-28FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00121ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2025-00121Globus MedicalExcelsiusGPSRead the record ↗Death reported2025-04-22FDA MAUDEIntuitive Surgical, Inc.da Vinci Surgical System2955842-2025-45559da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: A REVIEW OF AN ARTICLE WAS CONDUCTED, WHICH AIMED TO EVALUATE THE INITIAL EXPERIENCE AND FEASIBILITY OF ROBOTIC-ASSISTED PYLORUS-PRESERVING PANCREATICODUODENECTOMY PROCEDURES (PPPD) USING THE DA VINCI SP SYSTEM VERSUS THE DA VINCI XI SYSTEM. THE STUDY WAS A RETROSPECTIVE CASE SERIES ANALYZING 14 PATIENTS UNDERGOING PPPD FROM DECEMBER 2021 AND SEPTEMBER 2023. ONE PATIENT WITH COMMON BILE DUCT CANCER DIED DURING AT AN UNSPECIFIED TIME POST-PROCEDURE DUE TO THE PROGRESSION OF CANCER. THERE WAS NO REPORT OR INDICATION IN THE ARTICLE OF ANY DA VINCI SP SYSTEM MALFUNCTIONS. MULTIPLE ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION FROM THE CORRESPONDING AUTHOR WERE MADE; HOWEVER, NO RESPONSE HAS BEEN RECEIVED.
cause not established2955842-2025-45559Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2025-04-21FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00109ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT WHILE USING THE EXCELSIUS GPS SYSTEM, THE CASE WAS ABORTED AFTER BLEEDING WAS NOTICED. SHORTLY AFTER, THE PATIENT DISPLAYED SUSPECTED PRESENCE OF STROKE AND/OR HEMATOMA.
cause not established3004142400-2025-00109Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2025-04-18FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00123ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2025-00123Globus MedicalExcelsiusGPSRead the record ↗No injury reported2025-04-09Health CanadaRA-77225Aiper Seagull Pro ZT6001 Cordless Robotic Swimming Pool Vacuum Cleaner
Aiper Seagull Pro ZT6001 Cordless Robotic Swimming Pool Vacuum Cleaner — Large current adapter can overheat, posing burn and fire hazards. One unit caught fire in Canada while charging (March 2025); no injuries and no property damage beyond the unit. ~2,606 units sold in Canada Jul 2023-Apr 2024 via Best Buy Canada, Tanguay, Amazon. Consumers told to stop use and contact Aiper for a free replacement Scuba S1 cleaner.
cause not establishedRA-77225Read the record ↗Not graded by the source2025-04-08FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00120ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED.
cause not established3004142400-2025-00120Globus MedicalExcelsiusGPSRead the record ↗Property damage only2025-04NHTSAWaymoPhoenix30270-11297struck on the front right, bottom · proceeding straight
- Crash With
- Other, see Narrative
- Highest Injury Severity Alleged
- Property Damage. No Injured Reported
- SV Pre-Crash Movement
- Proceeding Straight
- SV Contact Area
- Front Right, Bottom
- SV Precrash Speed (MPH)
- 5
- CP Pre-Crash Movement
- Other, see Narrative
- CP Contact Area
- Unknown
- Within ODD?
- Yes
- Automation System Engaged?
- ADS
- Roadway Type
- Parking Lot
- Weather
- Cloudy
- Make
- JAGUAR
- Model
- I-PACE
SV is the subject vehicle — the one whose operator filed the report. CP is the crash partner, the other party. Contact area is where each was struck. NHTSA requires a report for any crash involving the driving system regardless of fault.
On April [XXX], 2025 at 7:21 AM MT a Waymo Autonomous Vehicle ("Waymo AV") operating in Phoenix, Arizona was in a collision involving a chain at a parking lot entrance at [XXX]. The Waymo AV was traveling westbound on [XXX] when it made a left turn into a parking lot at [XXX]. As the Waymo AV proceeded to enter the parking lot, the front of the Waymo AV made contact with a chain hanging across the entrance to the parking lot. At the time of the impact, the Waymo AV's Level 4 ADS was engaged in autonomous mode. The chain sustained damage. Waymo became aware of damage to the chain on June 26th, 2025. Waymo is reporting this crash under Request No. 2 of Standing General Order 2021-01. Waymo may supplement or correct its reporting with additional information as it may become available.
cause not established30270-11297WaymoSource file ↗Not graded by the source2025-04-01FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00015Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A SUCCESSFUL ROBOTIC BRONCHOSCOPY PROCEDURE, THE PATIENT DEVELOPED A PNEUMOTHORAX. A VALVE WAS PLACED AND PATIENT WAS HOSPITALIZED. NO DEVICE ISSUES WERE REPORTED.
cause not established3014447948-2025-00015Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-31FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00014Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A SUCCESSFUL ROBOTIC BRONCHOSCOPY PROCEDURE, THE PATIENT DEVELOPED A PNEUMOTHORAX. A CHEST TUBE WAS PLACED. NO SYSTEM ISSUES WERE REPORTED.
cause not established3014447948-2025-00014Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-28FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00013Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A ROBOTIC BRONCHOSCOPY PROCEDURE THE PHYSICIAN HAD DIFFICULTY WITH THE PATIENT SENSORS AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00013Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-26FDA MAUDEZimmer Biomet0009617840-2025-00011ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT THE PATIENT PRESENTED 3 WEEKS OR 3 MONTHS POST-OP WITH A FRACTURED FEMUR AT THE LOCATION WHERE THE FEMORAL REFERENCE PINS WERE INSTALLED. ADDITIONAL SURGICAL INTERVENTION WAS REQUIRED TO CORRECT THE FRACTURE. NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
cause not established0009617840-2025-00011Zimmer BiometRead the record ↗Not graded by the source2025-03-21FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00012Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING THE MONARCH BRONCHOSCOPY PROCEDURE, THE PHYSICIAN WAS PERFORMING THE BRONCHOALVEOLAR LAVAGE (BAL) WHEN THE PATIENT HAD A CARDIAC ARREST. THE PHYSICIAN WAS ABLE TO CONFIRM A PULSE BACK ON THE PATIENT. THE PATIENT IS IN STABLE CONDITION.
cause not established3014447948-2025-00012Auris HealthMonarch PlatformRead the record ↗Recall2025-03-20CPSCAiper25187
Aiper Seagull Pro Cordless Robotic Pool Vacuum Cleaners Recalled Due to Burn and Fire Hazards; Distributed by Shenzhen Aiper Intelligent Co. — Hazard: The recalled pool vacuum cleaner has a large current adapter that can overheat, posing burn and fire hazards. Reported incidents: The firm has received 19 reports of the recalled pool vacuums melting, smoking or catching on fire while charging causing five incidents of property damage. No injuries have been reported.
cause attributed by source25187AiperRead the record ↗Not graded by the source2025-03-20FDA MAUDEZimmer Biomet0009617840-2025-00008ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT HAS BEEN REPORTED THROUGH A MEDWATCH RECEIVED FROM THE FDA ALLEDGING OCCURANCES OF INACCURATE CUTS AND INCORRECT PLACEMENT OF IMPLANTS RESULTING IN PATIENT INJURIES. NO FURTHER INFORMATION IS CURRENTLY AVAILABLE.
cause not established0009617840-2025-00008Zimmer BiometRead the record ↗Not graded by the source2025-03-19FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00011Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT THE PHYSICIAN USED EBUS TO TARGET THE RIGHT UPPER LOBE (RUL). THE PHYSICIAN NOTICED THROUGH HIS MANUAL SCOPE THAT THERE WAS A SMALL LACERATION ON THE MUCOSA OF THE POST INTERIOR WALL OF THE RIGHT MAIN STEM. THE PHYSICIAN WAS NOT SURE HOW THIS OCCURRED. THE PHYSICIAN DECIDED TO ABORT THE CASE BECAUSE THEY DID NOT WANT TO CAUSE ANY FURTHER INJURY. THE PATIENT DID NOT EXPERIENCE ANY BLEEDING UPON WAKING UP. NOTABLY, THE ANESTHESIOLOGIST SUGGESTED THAT THE PATIENT MAY HAVE HAD FRAIL TISSUE, AND THE PHYSICIAN RECALLED A SIMILAR INCIDENT FROM TWO YEARS PRIOR IN THE SAME LOCATION, WHICH HAD RESOLVED WITHOUT COMPLICATIONS.
cause not established3014447948-2025-00011Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-13FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00009Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED DIFFICULTY NAVIGATING AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00009Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-12FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00149ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED AND ADJUSTED INTRA-OPERATIVELY.
cause not established3004142400-2025-00149Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2025-03-12FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00010Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER THE BRONCHOSCOPY PROCEDURE, THE PATIENT DEVELOPED MEDIASTINAL EMPHYSEMA, AS INDICATED BY THE POSTOPERATIVE CT EXAMINATION. AFTER A FOLLOW-UP CT SCAN DEMONSTRATED RECOVERY, THE PATIENT WAS DISCHARGED ON (B)(6), FOLLOWING A TOTAL HOSPITAL STAY OF 6 DAYS.
cause not established3014447948-2025-00010Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-11FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00008Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED SYSTEM FAULT MESSAGES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00008Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-03-07FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00007Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT AFTER A ROBOTIC BRONCHOSCOPY PROCEDURE, THE PATIENT HAD A PNEUMOTHORAX. A CHEST TUBE WAS PLACED AND THE PATIENT WAS MONITORED. THE PNEUMOTHORAX RESOLVED AND THE PATIENT WAS DISCHARGED HOME SIX DAYS AFTER THE PROCEDURE.
cause not established3014447948-2025-00007Auris HealthMonarch PlatformRead the record ↗Death reported2025-03-06FDA MAUDEIntuitive Surgical, Inc.da Vinci Surgical System2955842-2026-04766da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: A REVIEW OF AN ARTICLE WAS PERFORMED THAT EVALUATED OUTCOMES OF ROBOTIC INGUINAL HERNIA REPAIR (RIHR) IN A SINGLE INSTITUTION STUDY COMPARING SURGEONS WITH VARYING ROBOTIC EXPERIENCE. THE STUDY ANALYZED 297 PATIENTS UNDERGOING ROBOTIC INGUINAL HERNIA REPAIR BETWEEN JULY 2016 AND SEPTEMBER 2021. ONE PATIENT DIED WITHIN 30 DAYS POST SURGERY DUE TO ASPIRATION PNEUMONIA LEADING TO CARDIAC ARREST. NO DEVICE MALFUNCTIONS WERE REPORTED, AND THE AUTHORS DID NOT REPORT ANY EVENTS CAUSED BY ANY ISI DEVICE. INTUITIVE SURGICAL INC, (ISI) CONTACTED THE AUTHOR WHO REPORTED THAT THERE WERE NO ISSUES SEEN OR RECORDED WITH THE DA VINCI SYSTEM DURING THE STUDY. THE SYSTEM ITSELF DID NOT CONTRIBUTE TO THE DEATH IN THE STUDY WHICH WAS RELATED TO THE PATIENTS CO MORBIDITY AND NOT THE SURGERY ITSELF.
cause not established2955842-2026-04766Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Recall2025-03-06UK OPSS2409-0066Zodiac Freerider RF 5200 iQ wireless swimming pool robotic cleaner
Zodiac Freerider RF 5200 iQ wireless swimming pool robotic cleaner — OPSS product recall 2409-0066: Zodiac Freerider RF 5200 iQ robotic pool cleaner (batches 4923, 5123, 5223) recalled for fire risk after an injection-moulding defect compromised battery-block watertightness, allowing water contact with lithium batteries and risk of short-circuit/thermal runaway. Precautionary recall; no confirmed incidents stated in the notice.
cause not established2409-0066Read the record ↗Death reported2025-03-01FDA MAUDEIntuitive Surgical, Inc.da Vinci Surgical System2955842-2025-44952da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: A REVIEW OF THE CLINICAL ARTICLE WAS CONDUCTED, WHICH SUMMARIZED THE CLINICAL EXPERIENCE AND OUTCOMES OF TRANSORAL ROBOTIC SURGERY (TORS) IN THE TREATMENT OF HYPOPHARYNGEAL CARCINOMA. THE RETROSPECTIVE MULTICENTER STUDY ANALYZED 28 PATIENTS (ALL MALE, AGED 47- 82 YEARS) UNDERGOING TRANSORAL ROBOTIC SURGERY USING THE DA VINCI SI OR XI SURGICAL SYSTEM BETWEEN SEPTEMBER 2017 AND MARCH 2024. THE ARTICLE REPORTED TWO POSTOPERATIVE DEATHS WITHIN ONE MONTH OF SURGERY WITHOUT ANY OTHER DETAILS. NO DEVICE MALFUNCTIONS WERE REPORTED, AND THE AUTHORS DID NOT REPORT ANY EVENTS CAUSED BY THE DA VINCI SURGICAL SYSTEM. REQUESTS FOR ADDITIONAL INFORMATION WERE MADE TO THE CORRESPONDING AUTHOR, BUT NO RESPONSE HAS BEEN RECEIVED.
cause not established2955842-2025-44952Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2025-02-27FDA MAUDEZimmer Biomet0009617840-2025-00010ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT THERE WAS OVER RESECTION ON BOTH THE DISTAL FEMORAL AND PROXIMAL TIBIAL RESECTIONS, WITH A NET OVER RESECTION OF 4MM. THE CALIPER OF BONE MATCHED VALIDATED CUTS. PLANNED POLY WAS 10MM, RESULTING IN 13MM POLY WITH ADDITIONAL SOFT TISSUE RELEASES. THERE IS NO ADDITIONAL INFORMATION AVAILABLE.
cause not established0009617840-2025-00010Zimmer BiometRead the record ↗Not graded by the source2025-02-20FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00005Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED (VIA MEDSUN UF/IMPORTER REPORT # (B)(4)) THAT AFTER THE MONARCH BRONCHOSCOPY PROCEDURE THE PATIENT EXPERIENCED A PNEUMOTHORAX.
cause not established3014447948-2025-00005Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-02-18FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00006Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH PROCEDURE THE PHYSICIAN WAS UNABLE TO TURN THE BRONCHOSCOPE ON AFTER REMOVING THE SCOPE FROM THE PATIENT'S TRACHEA DUE TO THE CAMERA IMAGE BEING GRAINY AND ULTIMATELY GOING BLACK. THE PHYSICIAN ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00006Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-02-05FDA MAUDEZimmer BiometMW5165636ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: I LIVE WITH THE CHIEF TECHNOLOGY OFFICER FOR (B)(4), A DISTRIBUTORSHIP IN THE SOUTHEAST, FOR ZB CORPORATE. I HAVE OVERHEARD BUSINESS CALLS OF HOW THERE IS A PROBLEM WITH THE SOFTWARE ON THE ROBOTS AND THEY HAVE BEEN MAKING INCORRECT CUTS AND INCORRECT PLACEMENT OF IMPLANTS INTO PATIENTS FOR MONTHS. IT¿S A SYSTEM WIDE PROBLEM NOT JUST A FEW ROBOTS, MANY ROBOTS THEY HAVE OVER THE US ARE MALFUNCTIONING AND THEY HAVE YET TO FIGURE OUT THE EXACT CAUSE. IT¿S GONE AS HIGH UP THE CHAIN AS THE CEO BUT NOTHING IS BEING DONE. THEY HAVEN¿T SHUT DOWN USE. THEY JUST KEEP DOING INCORRECT AND IMMORAL SURGERIES ON PATIENTS AND NOT INFORMING THE DOCTORS THAT THEIR ROBOTS ARE THE REASON FOR THE POOR SURGERIES AND RESULTS. THEY HAVE BEEN TRYING TO FIX THE ISSUE AND COVER IT UP SINCE ZB FIRST BECAME AWARE. AS OF RIGHT NOW IT¿S NOT FIXED AND THEY ARE LETTING SURGEONS CONTINUE TO MAKE HARMFUL, PAINFUL IMPLANTS INTO PATIENTS. THEY¿VE FIRED ANYONE THAT CAME CLOSE TO DISCOVERING THE ISSUE. I LIVE WITH THE CHIEF TECHNOLOGY OFFICER FOR (B)(4), THE DISTRIBUTORSHIP FOR ZIMMER BIOMET IN THE SOUTHEAST DIVISION. THE ROSA ROBOT SOFTWARE HAS BEEN MALFUNCTIONING AND MAKING MISCUTS CONSTANTLY AND CAUSING HARM TO PATIE
cause not establishedMW5165636Zimmer BiometRead the record ↗Not graded by the source2025-02-05FDA MAUDEDePuy SynthesVELYS™ Robotic-Assisted Solution1818910-2025-03086VELYS
VELYS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: ADDITIONAL INFORMATION WAS RECEIVED AND STATES THAT: THE FRACTURE WAS CAUSED BY FAILURE TO CLEAR THE POSTERIOR ASPECT OF THE PS BOX. NETHER THE VELYS CUTS OR THE SAGITTAL SAW CUTS WERE THE BLAME.
cause not established1818910-2025-03086DePuy SynthesVELYS™ Robotic-Assisted SolutionRead the record ↗Not graded by the source2025-02-05FDA MAUDEZimmer BiometMW5165637ROSA Robotic Surgery
ROSA Robotic Surgery — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: I LIVE WITH THE CHIEF TECHNOLOGY OFFICER FOR (B)(6), A DISTRIBUTORSHIP IN THE SOUTH EAST, FOR ZB CORPORATE. I HAVE OVERHEARD BUSINESS CALLS OF HOW THERE IS A PROBLEM WITH THE SOFTWARE ON THE ROBOTS AND THEY HAVE BEEN MAKING INCORRECT CUTS AND INCORRECT PLACEMENT OF IMPLANTS INTO PATIENTS FOR MONTHS. IT¿S A SYSTEM WIDE PROBLEM NOT JUST A FEW ROBOTS, MANY ROBOTS THEY HAVE OVER THE US ARE MALFUNCTIONING AND THEY HAVE YET TO FIGURE OUT THE EXACT CAUSE. IT¿S GONE AS HIGH UP THE CHAIN AS THE CEO BUT NOTHING IS BEING DONE. THEY HAVEN¿T SHUT DOWN USE. THEY JUST KEEP DOING INCORRECT AND IMMORAL SURGERIES ON PATIENTS AND NOT INFORMING THE DOCTORS THAT THEIR ROBOTS ARE THE REASON FOR THE POOR SURGERIES AND RESULTS. THEY HAVE BEEN TRYING TO FIX THE ISSUE AND COVER IT UP SINCE ZB FIRST BECAME AWARE. AS OF RIGHT NOW IT¿S NOT FIXED AND THEY ARE LETTING SURGEONS CONTINUE TO MAKE HARMFUL, PAINFUL IMPLANTS INTO PATIENTS. THEY¿VE FIRED ANYONE THAT CAME CLOSE TO DISCOVERING THE ISSUE. I LIVE WITH THE CHIEF TECHNOLOGY OFFICER FOR (B)(6), THE DISTRIBUTORSHIP FOR ZIMMER BIOMET IN THE SOUTHEAST DIVISION. THE ROSA ROBOT SOFTWARE HAS BEEN MALFUNCTIONING AND MAKING MISCUTS CONSTANTLY AND CAUSING HARM TO PATI
cause not establishedMW5165637Zimmer BiometRead the record ↗Death reported2025-02-03FDA MAUDEIntuitive Surgical, Inc.da Vinci Surgical System2955842-2025-05720da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED MEDIASTINAL MASS RESECTION, THE BRACHIOCEPHALIC ARTERY WAS INJURED AND THE PROCEDURE WAS CONVERTED TO OPEN. THE PATIENT EXPIRED ON POST-OPERATIVE DAY ONE. THE SURGEON REPORTED THAT THE ARTERY WAS INJURED WHEN USING THE SYNCHROSEAL INSTRUMENT TO DISSECT LYMPH NODES. THE ARTERY WAS ADHERED TO TISSUE AND TO THE LYMPH NODES, RESULTING IN THE ARTERY NOT BEING VISIBLE TO THE SURGEON. THE ARTERY BEGAN TO BLEED AFTER IT WAS GRASPED WITH THE SYNCHROSEAL INSTRUMENT. THE PROCEDURE WAS CONVERTED TO THORACOTOMY. THERE WAS NO MALFUNCTION OF THE SYNCHROSEAL INSTRUMENT OR ANY OTHER DA VINCI PRODUCTS USED DURING THIS PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.
cause not established2955842-2025-05720Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗Not graded by the source2025-01-27FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00004Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN ENCOUNTERED SYSTEM FAULT MESSAGES AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00004Auris HealthMonarch PlatformRead the record ↗Not graded by the source2025-01-25FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00061ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY.
cause not established3004142400-2025-00061Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2025-01-16FDA MAUDEGlobus MedicalExcelsiusGPS3004142400-2025-00236ExcelsiusGPS
ExcelsiusGPS — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT SCREWS USING THE EXCELSIUS GPS SYSTEM WERE MISPLACED INTRA-OPERATIVELY AND THEN REMOVED AND REPLACED.
cause not established3004142400-2025-00236Globus MedicalExcelsiusGPSRead the record ↗Not graded by the source2025-01-14FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00003Monarch Platform
Monarch Platform — Injury report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT DURING A MONARCH BRONCHOSCOPY PROCEDURE THE PHYSICIAN WAS UNABLE TO QUERY PACS (PICTURE ARCHIVING AND COMMUNICATION SYSTEM) AND ELECTED TO ABORT THE CASE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
cause not established3014447948-2025-00003Auris HealthMonarch PlatformRead the record ↗Death reported2025-01-13FDA MAUDEAuris HealthMonarch Platform3014447948-2025-00002Monarch Platform
Monarch Platform — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: IT WAS REPORTED THAT THE PATIENT CODED DURING PROCEDURE, THE PHYSICIAN HAD CONDUCTED 4-BIOPSIES AND ON THE 5TH BIOPSY AN ABNORMAL AMOUNT OF BLOOD WAS COMING THROUGH THE ET TUBE. THE SCOPE AND THE PATIENT INTRODUCER WERE REMOVED AND THEY WERE ABLE TO STABILIZE THE PATIENT IN THE ROOM. THE PATIENT WAS MOVED TO ICU WHERE THEY LATER CODED AND PASSED AWAY. THE PHYSICIAN STATED THAT THE MONARCH DID NOT CAUSE OR CONTRIBUTE TO THE DEATH.
cause not established3014447948-2025-00002Auris HealthMonarch PlatformRead the record ↗Death reported2025-01-10FDA MAUDEIntuitive Surgical, Inc.da Vinci Surgical SystemMW5164582da Vinci Surgical System
da Vinci Surgical System — Death report filed with FDA (MAUDE). A MAUDE report does not establish that the device caused the outcome. Reported narrative: DRS. (B)(6), PLEASE NOTE, MS. (B)(6), WHO DIED WITHIN ONE YEAR FOLLOWING ROBOTIC MASTECTOMY FOR STAGE 2 BREAST CANCER: PLEASE NOTE - MS. (B)(6) CASE WAS ADVERTISED AS THE FIRST ROBOTIC MASTECTOMY OPERATION PERFORMED IN THE U.S. FOR TREATMENT OF BREAST CANCER: PLEASE NOTE, 5-YR SURVIVAL RATES FOR STAGE 2 BREAST CANCER USING THE CONVENTIONAL APPROACH TO MASTECTOMY IS OVER 80%. MS. (B)(6) DIED WITHIN ONE YEAR OF HER ROBOTIC MASTECTOMY SURGERY. PLEASE ENSURE THAT INTUITIVE SURGICAL HAS FORMALLY REPORTED THIS PATIENT MORTALITY FOLLOWING HER ROBOTIC MASTECTOMY TO THE FDA. ON JAN 5, 2025, AT 11:37 PM, (B)(6) WROTE: DRS. (B)(6), I AM WRITING THIS LETTER OF SAFETY AND ETHICS CONCERN/WARNING TO YOU BASED ON THE TWO RECENT HUMAN SUBJECT RESEARCH PUBLICATIONS FROM SOUTH KOREA, WHICH WERE SUPPORTED BY INTUITIVE SURGICAL: HTTPS://JAMANETWORK.COM/JOURNALS/JAMASURGERY/FULLARTICLE/2822315, HTTPS://WWW.NATURE.COM/ARTICLES/S41598-024-84807-0. THESE STUDIES INVOLVE THE USE OF THE DA VINCI ROBOTIC SYSTEM TO PERFORM MASTECTOMIES ON PATIENTS WITH BREAST CANCER, WHICH AS YOU KNOW WELL, IS CONSIDERED A NON-STANDARD AND OFF-LABEL APPROACH IN THE US AND WESTERN EUROPE. ADDITIONALLY, THESE EXPERIMENTAL SURGER
cause not establishedMW5164582Intuitive Surgical, Inc.da Vinci Surgical SystemRead the record ↗